TM-D700A/E
CIRCUIT DESCRIPTION
Attenuation band width
+25kHz or less at 40dB
Attenuation band width
+22kHz or less at 25dB
Guaranteed attenuation
80dB or more within fo -910kHz
(Spurious:20dB or more within +1MHz)
Guaranteed attenuation
80dB or more within fo -910kHz
(Spurious:40dB or more within +1 MHz)
Rippie
1dB or less
Ripple
1dB or jess
Insertion loss
3dB or less
Insertion loss
4dB or less
Termination impedance
5002 +5%, 6pF+0.5pF
Termination impedance
8000 +10%, 2pF+10%
Table1 MCF(L71-0491-05) (TX-RX Unit XF100)
Tabie4 MCF(L71-0409-15) (TX-RX Unit XF400)
Table2 Ceramic filter(L72-0979-05)
(TX-RX Unit CF101)
Table5 Ceramic filter(L72-0981-05)
(TX-RX Unit CF401)
terminating impedance
2.0kQ
terminating impedance
2,0kQ
Table3 Ceramic filter(L72-0971-05)
(TX-RX Unit CF100) (E type only)
Table6 Ceramic filter(L72-0980-05)
(TX-RX Unit CF400) (E type only)