7.4.7. Simple Resolution Real Time Adjustment
The 1st Lens Frame Unit is adjustment available in real time.
Rotate the three adjustment pins while monitoring bar graphic indicators. See details in below.
1st Lens Frame Unit
so that adjustment can be conducted.
7.4.6.1 Procedure of Simple Resolution Real Time Adjustment
③
(1)
Click "Real-Time Measurement.
The chart appears in real time on the screen.
(2)
*If no picture of the chart appears, do attempt to
change "DeviceNum" to 0, 1 or 2.
Green frames indicate the suitable point for measurement.
(3)
(they can be widened or narrowed)
Adjust three pins so that the all bar indicators go into OK(green).
(4)
If the bar graphic indicators do not obtain the OK(green), make sure
(5)
of setting & measurement environment and attempt adjustment.
As for Adjustment conditions/procedure, consult the "Operating Instructions" which is available in software package.
Peel off the glue around the pins
Adjustment Pin
②
Torx driver (RFKZ0609)
The adjustment of pins must be done
while the screws are slightly loosened.
(5.5Ncm±0.5Ncm)
(*) The new jig is optimized for workability.
If unavailable, use a flathead screwdriver instead.
①
④
Numerical value
Graphic indicator
33
5
Part No:
SUKZ000071(*)
④
Please rotate them little by little.
(30~45 degree)
5