Panasonic Lumix S-R24105 Service Training Manual page 27

Interchangeable lens for digital camera
Table of Contents

Advertisement

7.4.1.2 Setting to Simple Resolution Real Time Adjustment
(2) Checking Chart
(1) LED lamps
(1)
Install LED lights left and right symmetrically as uneven
illumination does not occur.
* The standard illuminance on the surface of all the 5 points of
the chart described as shown in the figure with red marking is
1500±150 lux.
Assemble the Checking Chart and paste the Chart with plastic
(2)
white board on a vertical wall.
* Checking Chart size : H 960mm x W 1440mm
(3)
Fix the Camera body and Lens to check on a tripod, and set the
distance from the Chart as below.
TELE end : About 4,200mm
WIDE end : About 960mm
* Housing space for performance checking is recommended
H:1,500mm x W:2,500mm x D:5,000mm and more.
(4)
After fine tune the installation position of the tripod, connect HDMI cable to Capture Board and transfer video data.
Branch data from the Capture Board to the PC and Monitor.
(5)
Connect HDMI cable to Monitor and display video data.
Connect USB cable to PC and execute Resolution Check software.
(6)
* Shoot the Chart and execute Resolution checking by analyzing the chart picture
(3) Lens and Master Body(DC-S1R)
25
(5) Monitor
HDMI cable
USB cable
(4) Capture Board
(6) PC Software
illuminance measurement point