Checking Outdoor Controller - Samsung AR07CSDAFWKN Service Manual

Multi air conditioner
Table of Contents

Advertisement

Troubleshooting

4-6-3 Checking Outdoor Controller

1. Making sure the wire connections.
2. Checking AC(220~240V) line
Caution!
When you remove PBA, you have to check DC link Voltage. After Power off, DC link Voltage is so high!
3. Checking DC voltage on each point
AJ020BXJ2CH, AJ024BXJ3CH (INVERTER PBA)
Item
Measuring point
DC LINK
CE151 Voltage
Main control 15V
CE161 Voltage
Main control 12V
CE175 Voltage
Main control 5V
CE174 Voltage
AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (MAIN PCB)
Item
Measuring point
12V
CE101Voltage
5V
CE105 Voltage
4. Checking PFCM
Check Resistance between R and S
AJ020BXJ2CH, AJ024BXJ3CH
PFCM
PFCM
R R
4-46
Nomal value
AC220V → 305~310Vdc
14.5V - 15.5V
10.8V - 13.2V
4.75V - 5.25V
Nomal value
10.8V - 13.2V
4.75V - 5.25V
AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (INVERTER PBA)
S S
Resistance
AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (INVERTER PCB)
Item
DC LINK
Main control 15V
Main control 12V CE157 Voltage
Main control 5V CE159 Voltage
R R
S S
Measuring point
Normal value
R - S
over the hundreds ㏀
Measuring point
Nomal value
CE151 Voltage
AC220V → 305~310Vdc
CE158 Voltage
14.5V - 15.5V
10.8V - 13.2V
4.75V - 5.25V