Product Checking And Parts Identification - Mitsubishi Electric FR-A720-00030-NA Instruction Manual

Table of Contents

Advertisement

Product checking and parts identification

1.1 Product checking and parts identification
Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to
ensure that the product agrees with your order and the inverter is intact.
• Inverter Model
FR -
A720
Symbol
Voltage Class
A720
Three-phase 200V class
A740
Three-phase 400V class
USB connector
RS-485 terminals
(Refer to page 337)
Connector for plug-in option connection
(Refer to the instruction manual of options.)
There are three connection connectors, and they are called
connector 1, connector 2, and connector 3 from the top.
Voltage/current input switch
(Refer to page 14, )
AU/PTC switchover switch
(Refer to page 188.)
EMC filter ON/OFF connector
(Refer to page 15)
Operation panel (FR-DU07)
(Refer to page 66)
Power lamp
Lit when the control circuit
(R1/L11, S1/L21) is supplied
with power.
Alarm lamp
Lit when the inverter is
in the alarm status
(Fault).
Front cover
(Refer to page 6)
Capacity plate
Capacity plate
FR-A720-00175-NA
Inverter model Serial number
 Accessory
· Fan cover fixing screws (FR-A720-00900 (FR-A740-
00440) or less) (Refer to Installation Guideline )
These screws are necessary for compliance with
the EU Directive
Capacity
00080 to 00175
00240 to 00460
00610 to 00900
00060 to 00090
00120 to 00310
00380, 00440
REMARKS
· For removal and reinstallation of covers, refer to page 6.
· For how to find the SERIAL number, refer to page 491.
2
00175
-
-
NA
Symbol
200V class
400V class
00030
00015
to
to
03460
09620
(Refer to page 368)
Overload Current Rating
SLD
110% 60s, 120% 3s
LD
120% 60s, 150% 3s
ND
150% 60s, 200% 3s
HD
200% 60s, 250% 3s
Screw Size (mm)
Quantity
M3 35
1
M4 40
2
M4 50
1
M3 35
1
M4 40
2
M4 50
1
Symbol
Symbol
Type number
Displays the rated
current
PU connector
(Refer to page 28)
Control circuit
terminal block
(Refer to page 26)
Main circuit
terminal block
(Refer to page 16)
Wiring cover
Rating plate
(Refer to page 18)
Rating plate
Inverter type
Input rating
Output rating
Surrounding air Temperature
40 C (104 F)
50 C (122 F)
Serial number
50 C (122 F)
50 C (122 F)
· DC reactor supplied (FR-A720-02880 (FR-A740-
01440) or more)
· Eyebolt for hanging the inverter (FR-A720-01250
to 03460, FR-A740-00570 to 05470)
Capacity
01150
01450 to 03460
00570
00710 to 02600
03250 to 05470
Specifications
Specifications
NA
U.S. specifications
N4
U.S. specifications (UL type 1)
Cooling fan
(Refer to page 439)
Charge lamp
Lit when power is supplied
to the main circuit
(Refer to page 16)
FR-A720-00175-NA
ND (50 C) XXA
LD (50 C) XXA
HD (50 C) XXA
SLD (40 C) XXA
Eyebolt Size Quantity
M8
2
M10
2
M8
2
M10
2
M12
2

Advertisement

Table of Contents
loading