Download Print this page

Product Checking And Parts Identification - Mitsubishi Electric FR-E700 Series Installation Manualline

Hide thumbs Also See for FR-E700 Series:

Advertisement

1 PRODUCT CHECKING AND PARTS IDENTIFICATION

Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to ensure that
the product agrees with your order and the inverter is intact.
Inverter model
-
FR
Symbol Voltage class
E740 Three-phase 400V class
E720S
Single-phase 200V class
Capacity plate
Capacity plate
Inverter model
FR-E740-095-EC
Serial number
Installation of the inverter
Enclosure surface mounting
Remove the front cover and wiring cover to fix the inverter to the surface.
FR-E720S-008(SC) to 030(SC)
Front cover
NOTE
When encasing multiple inverters, install them in parallel as a
cooling measure.
When using the inverters at the surrounding air temperature of
40°C or less, the inverters can be installed without any clearance
between them (0cm clearance). When surrounding air
temperature exceeds 40°C, clearances between the inverters
should be 1cm or more (5cm or more for the FR-E740-120(SC) or
more).
Install the inverter vertically.
-
E740
095
Displays the
rated current
Rating plate
Rating plate
Inverter model
Input rating
Output rating
Serial number
Wiring cover
- EC
Symbol
Control circuit terminal specification
Standard control circuit terminal
No symbol
(screw type)
SC
Safety stop function model
FR-E740-095-EC
FR-E740-016(SC) or more
FR-E720S-050(SC) or more
Front cover
10cm or more
10cm or more
Wiring cover
1

Hide quick links: