deTroubleshooting
Disturbance
and program
canceled.
Condensation in
condensation container
ter even though water drains
running hose connected
is closed.
Program starts
not.
Change program duration
changes during drying.
Pumping noise.
Whirring noise.
Drying time is too
long.
50
Cause and troubleshooting
Lay the water drain hose without kinks.
2.
Water drain hose is not connected correctly.
Make sure the water drain hose is connected
correctly.
→ "Connecting the water drain hose", page 14
Water drain hose is blocked.
Rinse the water drain hose with tap water.
The condensation water container filter is dirty.
"Cleaning the filter of the condensation water container",
page 46 .
A residual amount of condensation may remain in
the condensation container.
No error - no action necessary.
Water drain hose is not connected correctly.
Make sure the water drain hose is connected
correctly.
→ "Connecting the water drain hose", page 14
Parental controls are activated.
→ ""Deactivate parental controls", page 37
was not pressed.
Press .
No program set.
→ "Setting the program", page 33 .
1.
→ "Start the program", page 34 .
2.
Program flow is electronically optimized. This can lead
to a change in the program duration.
No error - no action necessary.
Condensation water pump active.
No error - normal operating noise.
Compressor ventilation active.
No error - normal operating noise.
Lint filter is contaminated.
"Cleaning the lint filter", page 35
Ambient temperature is higher than 30 °C.
Make sure the ambient temperature is below 30°C.

Advertisement