Sony Cyber-shot DSC-RX0M2 Service Manual page 32

Hide thumbs Also See for Cyber-shot DSC-RX0M2:
Table of Contents

Advertisement

2019/05/15 01:58:50 (GMT+09:00)
3.
Stick the kapton tape (polyimide sheet (2-580-751-01) cut) to the two microphone seats.
Kapton tape
4.
Remove the Label model number and Bottom spacer.
Label model number
Bottom spacer
Kapton tape
5.
Check that no dust is present on the vacuum pad, and push the vacuum pad perpendicularly against the to stick the vacuum pad.
Kapton tape
6.
Wait 30 seconds with keeping the pressure at near -5.0 kPa.
7.
Wait 30 seconds with setting air switch to "close", and record the indicated value (C).
Microphone seats
Caution :
This part cannot be reused. Discard the part removed
once in servicing. Instead, use a new part.
Caution :
Keep vacuum pad vertically by touching with finger.
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
OK
Air leak
Test hole
Sony CONFIDENTIAL
For Authorized Servicer
Tilt
NG
24
SYS SET