Leave the air leak tester for another 60 seconds, and record the indicated value (B).
Indicated
Air
value
pressure
-10.0kPa
-50.0kPa
-5.0kPa
-45.0kPa
-0.0kPa
-40.0kPa
FFF
Air switch: open
Measuring the Unit
1.
Turn on the air-leak tester.
2.
Hold the vacuum pad on flat surface, set the air switch to "open", and adjust the pressure to around -5.0 by turning the pressure
adjustment knob.
Inspection pressure: -45.0 ± 3.0 kPa
(A)
30sec
30sec
0kPa
Measurement
Air switch: close
Measure this amount of change.
Displayed values at measurement
points (A) and (B) are entered in
"AirLeak_CheckTool.exe"
(B)
to determine them.