Command generation axis monitor data

n: Axis No. - 1
Monitor item
[Md.345]
Command generation axis accumulative
position value
[Md.347]
Command generation axis position value
per cycle
*1 Command generation axis position units (Page 38 Command generation axis position units)
[Md.345] Command generation axis accumulative position value
The accumulative position value for the command generation axis is stored in the "[Pr.1] Unit setting". The axis whose unit
setting is other than "degree" is set to "command position value = accumulative position value".
[Md.347] Command generation axis position value per cycle
The position value per cycle for the command generation axis is stored in the range from 0 to ("[Pr.346] Command generation
axis length per cycle" - 1).
2 INPUT AXIS MODULE
46
2.2 Command Generation Axis
Storage details
The accumulative position value for the
command generation axis is stored.
Refresh cycle: Operation cycle
The position value per cycle for the
command generation axis is stored.
Refresh cycle: Operation cycle
Monitor value
■Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Command generation axis position units
■Monitoring is carried out in decimal.
0 to (Command generation axis length per
cycle - 1)
[Command generation axis position units
Buffer memory
address
61000+120n
61001+120n
*1
]
61002+120n
61003+120n
*1
]