Hour Meter Display; How To Reset The Hour Meter - Panasonic DVCPRO AJ-D455P Service Manual

Digital video cassette recorder/ component serial interface board/ digital video interface board/ cassette adapter
Hide thumbs Also See for DVCPRO AJ-D455P:
Table of Contents

Advertisement

7-2. Hour Meter Display

1. When the "
" and "
confirmed on the counter display part (front panel).
DIAG-MENU
H00 OPERATION
H01 DRUM RUN
H02 TAPE RUN
H03 THREADING
H11 DRUM RUN r
H12 TAPE RUN r
H13 THREADING r
H30 POWER ON
END
Video monitor

7-3. How to Reset the Hour Meter

DRUM RUN, TAPE RUN and THREADING information can be reset individually.
1.
Press the "EJECT" and "STOP" button simultaneously, and press the "DIAG" button. The Hour Meter page is
displayed on the video monitor (VIDEO OUT 3).
Set the cursor "* " to the indicated "r" mark item(item H11,12 or 13) by pressing the cursor buttons (5 or
2.
6 ). And press "RESET" button on the front panel, then the following message appears on the screen.
Press "PLAY" button to reset the hour meter or "STOP" button to ignore the reset.
3.
<Note>
Be careful, if press the "RESET" button more than 2 seconds when select the item H00-H03 and H30, the all hour
meter informations are reseted to ZERO.
" button is pressed during hour meter display, the operation hours for each item can be
HOURS METER
00000H
00000H
00000H
00000T
00000H
00000H
00000T
00000T
HOUR METER INIT SET
DRUM RUN r OK?
YES<PLAY> / NO <STOP>
H00-0000
Press the
" "
button.
H01-2000
Press the
" "
button.
Counter display part (front panel)
INF-11
Press the
" "
button.
Press the
" "
button.