DIAGNOSTIC CODES continued...
Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.
LiftMaster System
Code
Meaning
OPEN EYE/EDGE held more than 3 minutes
66
(expansion board)
67
Wireless edge triggered more than 3 minutes
68
Wireless edge loss of monitoring
Wireless edge triggered
69
CLOSE EYE/INTERRUPT triggered, causing
70
reversal, preventing close, or resetting TTC (main
board)
CLOSE EDGE triggered, causing reversal,
71
preventing close, or canceling TTC (main board)
OPEN EYE/EDGE triggered, causing reversal or
72
preventing opening (main board)
CLOSE EYE/INTERRUPT triggered, causing
73
reversal, preventing close, or resetting TTC
(expansion board)
CLOSE EYE/EDGE triggered, causing reversal and
74
preventing close or canceling TTC (expansion
board)
OPEN EYE/EDGE triggered, causing reversal or
75
preventing opening (expansion board)
Close input (EYE/EDGE) communication fault from
80
other operator
Open input (EYE/EDGE) communication fault from
81
other operator
Close input (EYE/EDGE) communication fault
82
(expansion board)
Open input (EYE/EDGE) communication fault
83
(expansion board)
Force Reversal
91
RPM / STALL Reversal
93
AC motor no start condition
95
99
Normal Operation
This manual downloaded from http://www.manualowl.com
TROUBLESHOOTING
Installed System
Informational
Solution
Check wired input on expansion board; check for alignment or
obstruction.
Check wired input for wiring issue or obstruction.
Check wireless edge inputs.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check inputs and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
Check inputs and communication method between operators, either
wired bus or radio. Ensure operator is powered. May have to erase the
wireless communication and reprogram the two operators.
Check inputs and communication method between operators, either
wired bus or radio. Ensure operator is powered. May have to erase the
wireless communication and reprogram the two operators.
Check the connections between the main board and the expansion
board.
Check the connections between the main board and the expansion
board.
Look for obstruction, if no obstruction, check that the mechanical
assembly is engaged and free to move. See section on Limit and Force
Adjustment, and Obstruction Test.
Check for obstruction. If no obstruction, check the operator cable
wiring and that the operator arm is engaged and free to move. Replace
RPM assembly.
Motor failed to start. Check for an obstructed gate or binding a
mechanism. Check start capacitor connections and condition.
No action required
External Entrapment
Protection
24
Inherent Entrapment
Protection
Saved
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES