To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.

EXPANSION BOARD REFERENCE

PLUG-IN LOOP DETECTOR INPUTS
For Plug-In Loop Detectors (Model LOOPDETLM)
SHADOW INTERUPT
EXIT
LOOP INPUTS
Page 13
OPEN
If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, then the gate will open and remain open until fault is cleared.
CLOSE
If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, faults are ignored (EXIT loop is faulted and inoperative).
NOT USED
OFF
When CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse.
ON
When CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause. Once the vehicle is clear the gate will continue to close.
ON
No change to the gate's normal operation.
OFF
When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close).
This manual downloaded from http://www.manualowl.com

EXPANSION BOARD

QUICK
ANTI TAIL
CLOSE
SWITCH
SWITCH
See below.
See below.

EXIT FAIL SWITCH

See below.

AC FAIL SWITCH

Not used.
EXIT FAIL SWITCH
AC FAIL SWITCH

ANTI TAIL SWITCH

QUICK CLOSE SWITCH

POWER
EYE
1
ONLY
EYE/
2
EDGE
EYE/
3
EDGE
COM
SBC
OPN
CLS
STP
COM
RELAY 2 WITH CORRESPONDING SWITCHES
Page 11
RELAY 1 WITH CORRESPONDING SWITCHES
Page 11
10
MAIN CONTROL BOARD CONNECTION
Connected at the factory.
EYES/EDGE TERMINALS
Page 12
CONTROL STATION TERMINALS
Page 12

Advertisement

Table of Contents
loading

Table of Contents