TECHNICAL SPECIFICATIONS

Supply voltage*:
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
Power consumption:
< 2.5 W
Mounting height:
2 m to 3.5 m
Temperature range:
-25°C to +55°C; 0-95% relative humidity, non condensing
Degree of protection:
IP54
Noise:
< 70 dB
Expected lifetime:
20 years
Detection mode:
Technology:
Output:
Test input:
Safety Standards:
BEA SA | LIEGE Science Park | Allée des Noisetiers, 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | info-eu@beasensors.com | www.beasensors.com
BEA hereby declares that the IXIO-DT1 is in conformity with European directives 2014/53/EU (RED), 2006/42/EC (Machinery) and 2011/65/EU (RoHS).
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089612
Angleur, february 2021
The complete declaration of conformity is available on our website
This product should be disposed of separately from unsorted municipal waste
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
In inverted frequency mode: pulsed signal in
detection (f = 2.5 Hz)
Estelle GRAAS
* The Equipment must be powered by a SELV limited
power source ensuring double insulation between pri-
mary voltages and the Equipment supply. The supply
current should be limited to max 3A.
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
2
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN ISO 13849-1 PL «c» CAT. 2
(under the condition that the door control system monitors
the sensor at least once per door cycle)
EN 16005
(protective devices)
DIN 18650-1
(protective devices)
EN 12978