Setting Tally; Setting Parallel Tally; Setting Serial Tally - Sony MVS-3000A System Startup Manual

Multi format switcher system
Hide thumbs Also See for MVS-3000A System:
Table of Contents

Advertisement

Setting Tally

Setting Parallel Tally

The red tallies for PRIMARY INPUTS 1 to 48 are
assigned to the TALLY connector on the switcher
processor by default.
For details about changing the assignment settings, refer
to the User's Guide.

Setting Serial Tally

Set the red tally of the program output (P/P PGM1) and the
green tally of the preview output (P/P PVW) to be output
from the SERIAL TALLY connector of the switcher
processor.
This section describes the procedure when "P/P PGM1" is
assigned to the OUTPUTS 1 connector and "P/P PVW" is
assigned to the OUTPUTS 2 connector.
1
Set the position of the MVS system in S-Bus space.
Device
Matrix Size
a Open the Engineering Setup >Router/Tally
>Router menu (7361).
b In the <Device> group, select the target device.
In this example, select [SWR1].
c In the <Matrix Size> group, select the matrix size.
In this example, select [136x138 (Standard)].
d Set each of the [Source], [Destination], and [Level]
parameters to "1".
28
Setting Tally
Source
Destination
Level
Router menu
2
Set the tally generation reference.
New
Tally Enable menu
Enable
New menu
a Open the Engineering Setup >Router/Tally >Tally
Enable menu (7364).
b Check the tally settings for the program output.
If the settings of "OUT001" are as follows, you do
not need to change the settings. Proceed to step g.
Setting
Destination Level Tally Type Enable
Value
OUT001
c Press [New].
The New menu (7364.1) appears.
d Set each of the [Destination Address], [Destination
Level], and [Tally Type] parameters to "1".
e In the <Tally Enable> group, select [Enable].
f Press [Execute].
Tally settings for program output
Destination Address
Destination Level
Execute
Tally Type
1
R1
Enable