4.6

Synchronous Control Change Function

Overview of synchronous control change function

This function can change the cam reference position, the cam axis position value per cycle and the position value per cycle
after the main/auxiliary shaft gear during the synchronous control.
The following 5 methods exist for the synchronous control change function. Refer to the following on each change command.
Page 132 Synchronous control change control data
Synchronous control change command
Cam reference position movement
Change cam axis position value per cycle
Change position value per cycle after main shaft
gear
Change position value per cycle after auxiliary
shaft gear
Cam axis position value per cycle movement

Synchronous control change control data

n: Axis No. - 1 (n: Axis No. - 17 for axis 17 to axis 32)
Setting item
Setting details
[Cd.406]
• Set "1" to initiate a synchronous control
Synchronous
change command request. The value is reset
control change
to "0" automatically after completion of the
request
synchronous control change.
Fetch cycle: Operation cycle
[Cd.407]
• Set the synchronous control change
Synchronous
command.
control change
Fetch cycle: At request (Synchronous control
command
change request)
[Cd.408]
• Set the change value for synchronous control
Synchronous
change processing.
control change
Fetch cycle: At request (Synchronous control
value
change request)
[Cd.409]
• Set the reflection time for synchronous
Synchronous
control change processing.
control reflection
Fetch cycle: At request (Synchronous control
time
change request)
*1 Set the value as follows in a program.
0 to 32767: Set as a decimal.
32768 to 65535: Convert into a hexadecimal and set.
[Cd.406] Synchronous control change request
Set "1" to initiate "[Cd.407] Synchronous control change command". The Simple Motion module resets the value to "0"
automatically after completion of the synchronous control change.
The setting is initialized to "0" when starting synchronous control.
4 ADVANCED SYNCHRONOUS CONTROL
132
4.6 Synchronous Control Change Function
Application
Adjust the cam reference position by the
movement amount.
Change the cam axis position value per cycle.
Change the position value per cycle after main
shaft gear.
Change the position value per cycle after auxiliary
shaft gear.
Adjust the phase of the cam axis by the movement
amount.
Setting value
■Set in decimal.
1: Synchronous control change
request
■Set in decimal.
0: Cam reference position movement
1: Change cam axis position value per
cycle
2: Change position value per cycle
after main shaft gear
3: Change position value per cycle
after auxiliary shaft gear
4: Cam axis position value per cycle
movement
■Set in decimal.
-2147483648 to 2147483647
(Refer to the detailed explanation for
units.)
■Set in decimal.
0 to 65535 [ms]
Output axis operation
Operated
None
None
None
Operated
Default
value
0
0
0
0
*1
Buffer memory address
Axis 1 to
Axis 17 to
axis 16
axis 32
44086+20n
1044086+20n
44087+20n
1044087+20n
44088+20n
1044088+20n
44089+20n
1044089+20n
44090+20n
1044090+20n

Advertisement

Table of Contents
loading

Table of Contents