Installation - Graco 918372 Instructions Manual

Air-powered ram supply un
Table of Contents

Advertisement

The installation procedure includes:
grounding the system
locating and installing the ram
installing the pump in the ram (if pump and ram are
not already assembled)
Ground the System
WARNING
FIRE AND EXPLOSION HAZARD
When installing the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 4.
To reduce the risk of static sparking, ground the pump,
object being sprayed, and all other spraying/dispensing
equipment used or located in the spraying/dispensing
area. Check your local electrical code for detailed
grounding instructions for your area and type of equip-
ment.
1. Pump: connect the ground wire and clamp to a
true earth ground as shown in Fig. 2.
a. Loosen the grounding lug locknut (W) and
washer (X).
b. Insert one end of the 1.5 mm
mum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely.
c. Connect the other end of the wire to a true
earth ground.
To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
spray gun/dispensing valve firmly to the side of a
grounded metal pail, then trigger the gun/valve.
w
Y
Fig. 2

Installation

2. Fluid and air hoses: use only electrically conduc-
3. Air compressor: follow the manufacturer's recom-
4. Spray gun or dispensing valve: connect to a prop-
5. Fluid supply container: according to local code.
6. Object being sprayed: according to local code.
7. Dispense gun: obtain grounding through the con-
8. All solvent pails used when flushing: according to
Locating the Ram
To locate the ram, follow one of the procedures below.
Refer to the Ram Mounting and Clearance Dimensions
drawing (Fig. 7 on page 67) for ram mounting and
clearance dimensions.
2
(12 ga) mini-
Bolting the Ram to the Floor
To install the ram in a permanent location:
1. Select a convenient location for the equipment.
2. Level the base of the ram, using metal shims.
3. Using the holes in the base as a guide, drill holes
4. Bolt the ram to the floor anchors, which must be
X
Z
5. Now you are ready to install the pump. Go to the
Securing the Ram to a Mobile Platform
When performing the following procedure, use the
Mobile Platform Kit (918414) to secure the ram to a
mobile platform.
tive materials and air hoses, and fluid hoses.
mendations.
erly grounded fluid hose and pump.
nection of the hose, or cable.
your local code. Use only metal pails, which are
conductive, placed on a grounded surface. Do not
place the pail on a nonconductive surface, such as
paper or cardboard, which interrupts the grounding
continuity.
Check that there is sufficient overhead clearance
for the pump and ram when the ram is in the fully
raised position. Make sure the air regulators for the
pump and ram are fully accessible.
for 1/2 in. (13 mm) anchors.
long enough to prevent the unit from tipping. Refer
to the Dimensional Drawing on page 67.
Installing the Pump section on page 11.