1
Figure 9
9. Relocate plastic spacer/bushing (Figure 9) on bottom
of door to the opposite side. Clean out bushing hole in
door bottom if necessary.
Figure 10
10. Place door on lower hinge pin. Align flat edge of top
hinge with outer edge of unit and fasten upper hinge
to unit (four screws) (Figure 10). Partially tighten
screws until door is aligned.
11. Adjust door to assure proper seal. Tighten upper and
lower hinge screws securely.
12. Replace four plastic plugs removed in Step 4 into holes
on top of unit. Replace screws in holes in bottom of unit
on opposite side.
13. Replace the grille.
06/2006
1175R, 1175WC and 1175BEV Models
ULIN_0109_A
ULIN_0110_A
7

Other Site Requirements

Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on Page 11.
Environmental Requirements
Many U-Line models are designed to operate in harsh
outdoor/marine environments. Special considerations
include the following:
(1175 REFRIGERATOR requirements)
• The units are designed to operate between 50°F (10°C)
and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit's ability to reach
low temperatures and may also reduce the ice
production rate for those models with icemakers.
• If the ambient temperature is expected to drop below
45°F (7°C), drain all water from the unit to prevent
freezing damage not covered by the warranty.
• For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
• For best performance and life outdoors, place under a
counter or provide shelter of some kind.
• In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.
(1175 WC & 1175 BEV requirements)
• The units are designed to operate between 50°F (10°C)
and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit's ability to reach
low temperatures.
• For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
• In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.
• U-Line does not recommend installation of glass front
®
models (Wine Captain
Beverage Centers) as well as the Combo Drawer model
(Refrigerator/Freezer/Ice Maker) outdoors, or in
tropical climates where high humidity and dew point
are present on a regular basis, unless air-conditioning
(typical 72°F, 75%RH) will be used.