Samsung NZ64R3525CK User & Installation Manual page 12

Ceramic glass hob
Table of Contents

Advertisement

Installation
> 25 and ≤ 32
1N~
2N~
> 10 and ≤ 16
The connection must be carried out as shown
in the diagram. The connecting links should be
fitted according to the appropriate connection
diagram.
The earth lead is connected to terminal. The
earth lead must be longer than leads carrying
electric current.
The cable connections must be made in accor-
dance with regulations and the terminal screws
tightened securely.
The connecting cable is to be secured with
the mains cable cleat and the covering closed
by pressing firmly (locking into place). Before
switching on for the first time, any protective
foil or stickers must be removed from the ce-
ramic glass surface.
Once the hob is connected to the mains
supply, check that all cooking zones
are ready for use by briefly switching
each on in turn at the maximum setting.
Warning: The electrical connection of
this appliance should be carried out by
an authorised service person or quali-
fied electrician, according to the in-
structions in this guide and in compli-
ance with the current local regulations
Warning: The appliance must be
earthed.
Before connecting the appliance to the
power supply, the voltage rating of the
appliance (stamped on the appliance
identification plate) must be checked for
correspondence to the available mains
supply voltage, and the mains electric
wiring should be capable of handling the
12 English
All manuals and user guides at all-guides.com
> 4 and < 6
> 1.5 and <
2.5
appliance's power rating (also indicated on
the identification plate).
During installation, please ensure that
isolated cables are used. An incorrect
connection could damage your appliance.
If the mains cable is damaged and needs
to be replaced this should be done by a
qualified person.
Do not use adaptors, multiple sockets and/
or extension leads.
The supply cord should be kept away from
hot parts of the appliance and must not be
bent or compressed. Otherwise the cord
may be damaged, causing a short circuit.
• If the appliance is not connected
to the mains with a plug, a all-pole
disconnector switch (with at least 3 mm
contact spacing) must be used in order
to meet the safety regulations.
• The appliance is designed for a power
supply of 220-240V ~ and 380-415V
3N~. If your supply is different, contact
the authorised service person or a
qualified electrician.
• The power cable (H05VV-F) must be
long enough to be connected to the
appliance, even if the appliance stands
on the front of its cabinet.
• Ensure all connections are adequately
tightened.
• Fix the supply cable in the cable clamp
and then close the cover.
• The terminal box connection is placed
on the terminal box.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz64r3525eg

Table of Contents