Advertisement

Quick Links

B. Connect the other end of the cable to the
network devices such as routers, Ethernet
switches or NVRs (network video recorders).
Step 4: Connect your FSD-604HP to PoE PDs.
A. Connect one end of a standard network
cable to one of the four 10/100Mbps RJ45
PoE+ ports of the FSD-604HP.
B. Connect the other end of the cable to the
802.3at/af PD.
Office Building
Office Area
Fixed IP Dome
IEEE 802.3af PoE
VoIP Phone
PoE
DC
IEEE 802.3af PoE Splitter
FSD-604HP
PoE
PoE
PoE Extender
PoE
IEEE 802.3at
Control Room
PoE IP Camera
IEEE 802.3af
PoE IP Camera
Office Building
Warehouse
Power Line (DC)
DC
100BASE-TX UTP
100BASE-TX UTP with PoE
PoE
- 9 -
Cable distance for Switch
 If the "DIP Switch Mode" is set to
"Standard", then the distance between
the FSD-604HP and PC/PD should not ex-
ceed 100 meters for UTP/STP cable.
Note
 If the "DIP Switch Mode" is set to "Ex-
tend", then the distance between the
FSD-604HP and PC/PD should not exceed
250 meters.
Make sure the wiring is correct
Category 3/4/5 cable can be used in 10
Mbps operation. To reliably operate your
network at 100Mbps, you must use an un-
shielded twisted-pair (UTP) Category 5/5e
Note
cable, or better data grade cabling. While a
Category 3 or 4 cable may initially seem to
work, it will soon cause data loss.
Step 5: Supply power to the FSD-604HP.
A. Connect one end of the power cable to the
Switch.
B. Connect the power plug of the power cable
to a standard wall outlet.
When the Switch receives power, the power LED should
remain solid Orange.
- 10 -
Questo manuale d'istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per
o cerca il tuo prodotto tra le
migliori offerte di Switch
Wall-mount Installation
Step 1: Please find the wall that can mount the
FSD-604HP.
Step 2: Please refer to the picture below and screw the
two screws on the wall.
122mm
Step 3: Hang the FSD-604HP on the screws from the
wall.
Step 4: Repeat step 5 of Desktop Installation for
power supply to the FSD-604HP.
Before mounting the device to the wall,
please check the location of the electrical
outlet and the length of the Ethernet cable.
Note
- 11 -
7. Product Specifications
FSD-604HP
Model
4-Port 10/100Mbps 802.3af/at PoE +
2-Port 10/100Mbps Desktop Switch
Hardware Specifications
6-Port RJ45 for 10/100BASE-TX, auto
Network Connector
MDI/MDIX
4-Port with 802.3af/at PoE injector
PoE Inject Port
function (Port 1 to port 4)
System: Power (Orange)
Per PoE port: PoE (Orange, port 1 to
LED Display
port 4)
LNK/ACT (Green, port 1 to port 6)
Distance in Standard mode is 100M
DIP Switch
Distance in Extend Mode is 250M
Base on the cable category
Switch Architecture
Store and Forward switch architecture
2K MAC address table with auto
MAC Address Table
learning function
ESD Protection
6KV
Switch Fabric
1.2Gbps
Switch Throughput
0.89Mpps @64bytes
Maximum Packet Size
1536bytes
Back pressure for half duplex. IEEE
Flow Control
802.3x pause frame for full duplex
Power Requirements
AC 100~240V, 2A max.
Power Consumption
Max. 63 watts, 214 BTU
Dimensions (W x D x H) 168 x 93 x 32mm
Weight
499g
- 12 -
Power over Ethernet
IEEE 802.3af Power over Ethernet/PSE
PoE Standard
IEEE 802.3at Power over Ethernet Plus/
PSE
PoE Power Supply Type End-span
Power Pin Assignment
1/2 (+), 3/6(-)
Per Port 52V DC, 300mA. max. 15.4
watts (IEEE 802.3af)
PoE Power Output
Per Port 52V DC, 600mA. max. 30
watts (IEEE 802.3at)
PoE Power Budget
60 watts
Number of PDs (7 watts) 4
Number of PDs
4
(15.4 watts)
Number of PDs
2
(30 watts)
Standard Conformance
EMI Safety
CE, FCC
IEEE 802.3
Ethernet
IEEE 802.3u
Fast Ethernet
Standard Compliance
IEEE 802.3x
Flow Control
IEEE 802.3af
Power over Ethernet
IEEE 802.3at
Power over Ethernet Plus
Environment
Operating Environment
0 ~ 50 degrees C
Storage Environment
-10 ~ 70 degrees C
5 ~ 95%, relative humidity, non-
Operating Humidity
condensing
5 ~ 95%, relative humidity, non-
Storage Humidity
condensing
- 13 -
Planet FSD-604HP
8. Customer Support
Thank you for purchasing PLANET products. You can
browse our online FAQ resource on PLANET Website
first to check if it could solve your issue. If you need
more support information, please contact PLANET switch
support team.
PLANET online FAQ:
http://www.planet.com.tw/en/support/faq.php?type1=1
Switch support team mail address:
support_switch@planet.com.tw
Copyright © PLANET Technology Corp. 2017.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All
other trademarks belong to their respective owners.
- 14 -

Advertisement

Table of Contents
loading

Summary of Contents for Planet FSD-604HP

  • Page 1 Fixed IP Dome IEEE 802.3af PoE VoIP Phone IEEE 802.3af PoE Splitter FSD-604HP 122mm Step 3: Hang the FSD-604HP on the screws from the PoE Extender IEEE 802.3at wall. Control Room PoE IP Camera Step 4: Repeat step 5 of Desktop Installation for power supply to the FSD-604HP.
  • Page 2: Package Contents

    1. Package Contents Check the following contents of your package: FSD-604HP User’s Manual Foot Pad Power Cord If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.
  • Page 3: Product Features

    2. Product Features  RJ45 Interface  6-port 10/100TX Ethernet RJ45 copper  4-port IEEE 802.3at/af PoE Injector (Port-1 to Port-4)  Power over Ethernet  Complies with IEEE 802.3af/at Power over Ethernet end-span PSE  Up to 4 IEEE 802.3af/2 IEEE 802.3at devices powered ...
  • Page 4  Switching  Hardware-based 10/100Mbps auto-negotiation and auto MDI/MDI-X  Flow control for full duplex operation and back pressure for half duplex operation  1536bytes packet size  Integrates address look-up engine, supporting 2K absolute MAC addresses  Automatic address learning and address aging ...
  • Page 5: Switch Front Panel

    3. Switch Front Panel Figure 3-1 shows the front panel of the FSD-604HP. PoE In-use FSD-604HP Standard Uplink Extend Figure 3-1: FSD-604HP Front Panel The front panel of the FSD-604HP provides one DIP switch for “Standard” and “Extend” mode selections.
  • Page 6 PoE IP Camera Standard Extend FSD-604HP Power 250 meters (820 feet) 100BASE-TX UTP with PoE 10BASE-T UTP with PoE After changing the mode, you need to manually restart the FSD-604HP to make the corresponding configuration take effect. Note - 5 -...
  • Page 7: Led Indicators

    4. LED Indicators System Color Function Lights to indicate the Switch has Orange power. Per 10/100Mbps Port Color Function Lights to indicate the port is Orange providing 52V DC in-line power to remote PoE PD. Lights to indicate the link through that port is successfully established at 10/100Mbps.
  • Page 8: Switch Rear Panel

    5. Switch Rear Panel Figure 5-1 shows the rear panel of the FSD-604HP. 100~240V AC 50/60Hz Figure 5-1: FSD-604HP Rear Panel 1. The device is a power-required device, meaning it will not work till it is pow- ered. If your networks should be active...
  • Page 9: Installing The Switch

    6. Installing the Switch This part describes how to install your FSD-604HP and make connections to it. Please read the following topics and follow the procedures as presented. This FSD-604HP does not need software configuration. Note Desktop Installation To install the FSD-604HP on desktop, simply follow the...
  • Page 10 B. Connect the other end of the cable to the network devices such as routers, Ethernet switches or NVRs (network video recorders). Step 4: Connect your FSD-604HP to PoE PDs. A. Connect one end of a standard network cable to one of the four 10/100Mbps RJ45 PoE+ ports of the FSD-604HP.
  • Page 11 Cable distance for Switch  If the “DIP Switch Mode” is set to “Standard”, then the distance between the FSD-604HP and PC/PD should not ex- ceed 100 meters for UTP/STP cable. Note  If the “DIP Switch Mode” is set to “Ex- tend”, then the distance between the...
  • Page 12 Step 2: Please refer to the picture below and screw the two screws on the wall. 122mm Step 3: Hang the FSD-604HP on the screws from the wall. Step 4: Repeat step 5 of Desktop Installation for power supply to the FSD-604HP.
  • Page 13: Product Specifications

    7. Product Specifications FSD-604HP Model 4-Port 10/100Mbps 802.3af/at PoE + 2-Port 10/100Mbps Desktop Switch Hardware Specifications 6-Port RJ45 for 10/100BASE-TX, auto Network Connector MDI/MDIX 4-Port with 802.3af/at PoE injector PoE Inject Port function (Port 1 to port 4) System: Power (Orange)
  • Page 14 Power over Ethernet IEEE 802.3af Power over Ethernet/PSE PoE Standard IEEE 802.3at Power over Ethernet Plus/ PoE Power Supply Type End-span Power Pin Assignment 1/2 (+), 3/6(-) Per Port 52V DC, 300mA. max. 15.4 watts (IEEE 802.3af) PoE Power Output Per Port 52V DC, 600mA.
  • Page 15: Customer Support

    Switch support team mail address: support_switch@planet.com.tw Copyright © PLANET Technology Corp. 2017. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. - 14 -...

Table of Contents