NOTE: W hen charging is necessaw-
during heating s eason,
charge must beweighed inaccordance
with unit r ating p late ÷ 0.6
ozift o f3/8-in. liquid lineabove orbelow 15ft respectively.
EXAMPLE:
Tocalculate additional
charge required fora
25 ft line set:
25 fi
15 ft
10 ft X 0.6 ozit't
6 oz of additional
charge
Step
15--Final
Checks
mNPORTANT:
Before
leaving
job, be sure to do the fbltowing:
1. Securely
fitsten all panels
and covers.
2. Tighten
service valve=stem
caps to 1i12=mm
past finger-tight.
3. Leave
L ser's
Manual
with owner
Explain
system
operation
and periodic
maintenance
requirements
outlined
in manual.
4. Fill out Dealer
Installation
Checklist
and place
in customer
file.
CARE
AND MAINTENANCE
For continuing
high per%m_ance
and to minimize
possible
equip=
ment
failure,
periodic
maintenance
must
be perfbm_ed
on this
equipment
Frequency
of maintenance
may vary depending
upon
geographic
areas,
such as coastal
applications
Copyright
2002
CARRIER
Corp.
_ 7310
W.
Morris
St
• Indianapolis.
IN 46231
38byc3si
Manufacturer
reserves
the
right
to discontinue,
or
change
at any
time,
specifications
or designs
without
notice
and
without
incurring
obligations.
B°°k
1h_
PC 101
catalog
No.
533-80078
Printed
in USA
Form
38BYC-3SI
Pg 8
11-02
Replaces:
38BYC-2SI
Tab
15al 5a

Advertisement

loading

This manual is also suitable for:

38byg