Carrier 38BYC Installation And Start-Up Instructions Manual page 3

12 seer split system heat pump

Advertisement

If TXV installation
is required,
remove
existing
AccuRater_
t'rom
indoor
coil
Re_r
to Figs
4 and 5 and install TXV kit as _bllows:
1_ Install
suction
robe adapter_
2. Install
liquid
flareoto-sweat
adapter.
3. Connect
external
equalizer
robe
to fitting
on suction
robe
adapter.
4. Position
sensing
bulb
on horizontal
portion
of suction
robe
adapter.
Secure
using
supplied
hardware.
5. Insulate
bulb aRer installation.
(See Fig. 5.)
d. Leak check
all connections.
feeder
tubes, there is a 3/%in.
O.D. stub robe approximately
2 in.
tong. (See Fig. 60 The defrost
thermostat
should be located
on stub
mbe_ Note
that there is only
1 stub robe used with
liquid header,
and on most units
it is the bottom
circuit_
f
STUB TUBE
DEFROST
THERMOSTAT
BULB
UALIZER
TUBE
EXPANSION
VALVE
Fig. 4--Typical
TXV Insta!lation
O'CLOCK
2
SENSING
A88382
L-_'S
UCTIO N
8 O'CLOCK
4 O'CLOCK
7_ IN. OD & SMALLER
LARGER
THAN
7_ IN. OD
A81032
Fig. 5--PositioNng
of Sensing
Bulb
Step
7--Check
Outdoor
AccuRater®
Piston
(beck
outdoor unit piston
Remove
retainer
on liquid service valve
and check piston size with n_atching
nm'uber
listed on outdoor
unit
rating
plate.
Step
8--Check
Defrost
Thermostat
(heck
defiost
thermostat
to ensure
it is properly
located
and
securely
attached
There is a liquid header with a brass distributor
and feeder
robe
going
into outdoor
coil
At the end of 1 of the
A97517
Fig. 6--Defrost
Thermostat
Location
Step
9--Make
Piping
Connections
Relieve
pressure
and recover
all refi'igerant
before
system
repair
or final unit disposal
to avoid personal
ir_.iuI?' or death.
Use all service
ports
and
open
all flow
control
devices,
including
solenoid
valves.
If ANY refrigerant robing is buried, provide a 6 in. vertical
rise at service valve, Ret'rigerant robing lengths up to 36 in,
may be buried without further special consideration.
For
lengths longer than 36 in., refer to Application Guideline and
Service Manual
Residential Split System Air ( onditioners
and Heat Pumps,
To prevent
damage
to unit
or service
valves
obsela'e
the
fbllowing:
*Use a brazing
shield
*Wrap
service
valves
with
wet
cloth
or use
a heatosink
material
Outdoor
units may be connected
to indoor
section using accesso_
robing package
or field-supplied
refrigerant
grade robing of coll'ect
size and condition
For robing requirements
beyond
50 it, substan-
tial capacity
and
per_brmance
losses
can occur
Following
the
recommendations
in
the
Residential
Split
System
Long-Line
Application
Guideline
will redtlce
these
losses.
Ret'cr to Table
1
for
field
tubing
equivalent
line
length
Refer
to
Table
2 _br
accessory
requirements
For buried
line applications
greater than 36 in., refer to Table 2 and
Residential
Split
System
Buried
Line
Application
Guideline.
Buried
line applications
may not exceed
100 t't.
If refrigerant
tubes or indoor
coil are exposed
to atmosphere,
they
must be evacuated
to 500 microns
to eliminate
contamination
and
moisture
in the system