Electrical Connection
6.2.3 Battery Connection
CAUTION!
Never reverse the polarity of the battery cables as this will
result in inverter damage. Always ensure correct polarity.
Charging and Discharging system of EVERVOLT Hybrid inverter is designed for
high-voltage lithium-ion battery.
As a Lithium-ion battery will be connected with EVERVOLT Hybrid inverter, the
battery communication should be compatible with EVERVOLT Hybrid inverter and
the BMS must be connected between inverter and battery.
• Battery connection diagram for Lithium-ion battery
EVERVOLT Hybrid
BAT Port
Inverter
BMS Port
Ÿ
BAT terminal connection
CAUTION!
DANGER — HIGH VOLTAGE!
Make sure the breaker of battery is in OFF position.
48
Lithium-ion Battery
A
B
C
On the side of inverter
BMS
DIP
B
BAT+
BAT-
POWER
C
A
On the side of battery
A: BAT+
B: Communication connection
1 The BAT+ (red) , communication cable and BAT- (black) cables have been
already connected on the inverter's side. Only connecting the other end of the
cables to the corresponding port of BMS is needed.
2 Make sure that both ends of the cables are connected correctly to the connector
on the right side of the BMS module.
Electrical Connection
Inverter
Battery
C: BAT-
49