Pump Strainer Cleansing Procedure - Lincoln Electric FlexCool 35 Operator's Manual

Table of Contents

Advertisement

FLEXCOOL
35

pUMp STRaineR cleanSinG pRoceDURe

1. Remove the cooler drawer as described earlier.
2. While holding the pump head securely, remove the 15/16"
acorn nut from the pump body. be prepared for some coolant
to escape from the pump when removing the nut.
3. Gently pull the strainer to remove it from the pump. See
FIGURE D.4
Figure D.4
4. Clean and remove any debris from the strainer. Replace the
strainer if it is damaged or excessively dirty.
5. Reinsert the strainer into the pump body.
6. Replace the 15/16" nut and torque to 6.25 ft-lbs (8.5 N-m)
with the pump head securely.
7. Insert the cooler drawer back in the cabinet and secure with 2
screws at the front.
D-3