Foot controller 1 polarity setting (FC1 Polarity)
Foot controller 2 polarity setting (FC2 Polarity)
Default value: STANDARD
This setting lets the RD-600 match the polarity of the expression pedal or pedal switch that is
connected to the rear panel FC1 or FC2 pedal jack. If you are using a Roland pedal switch (such
as the DP-2), set this to STANDARD.
If you are using a pedal switch with opposite polarity made by another manufacturer, set this
to REVERSE.
SFC Polarits
Range of values: STANDARD, REVERSE
FCI FS TAHDARD
Damper pedal polarity setting (DamperPolarity)......Default value: STANDARD
This setting lets the RD-600 match the polarity of the pedal switch that is connected to the rear
panel damper pedal jack. If you are using a Roland pedal switch (such as the DP-2), set this to
STANDARD.
If you are using a pedal switch with opposite polarity made by another manufacturer (ie., if
the damper effect is applied even though you are not pressing the pedal), set this to REVERSE.
SDanrerPolaritue
Range of values: STANDARD, REVERSE
& SO TAHHOARE
Using MIDI program changes to select setup memories
(Control
Ch.)
walbiceudeeeucccdkasvadecdoudsaxaenasescroibaksianiadiaasess
DOTAUIT
value:
OFF
You can specify a channel that will be used for selecting setup memories. If this channel coin-
cides with the receive channel of an internal part, program change messages received on that
channel will select setup memories instead of selecting Tones. If this parameter is turned OFF,
incoming program change messages will not select setup memories.
* The receive channel for each part is specified by the internal part parameters (p.45).
SCornteol
Ch,
_
Range of values: OFF, 1-16
FOFF
Setup memories correspond to program number as follows.
Si1
1
$12
2
S13
3
S14
4
S15
5
S16
6
S17
7
S18
8
S21
9
$22
10
S23
11
$24
12
$25
13
S26
14
$27
15
S28
16
$31
17
$32
18
S33
19
S34 20
S35 21
S36 22
S37 23
S38 24
$41
25
S42 26
S43 27
S44
28
S45 29
S46 30)
S47 31
$48 32
$51
33
$52 34
$53 35
S54
36
S55
37
S56 38
S57 39
S58 40
S61
41
S62 42
S63 43
S64
44
S65 45
S66 46
S67 47
S68 48
$71
49
S72 50
S73 51
$74
52
$75
53
S76 54
$77
55
S78 56
S81
57
S82 58
S83 59
S84
60
S85 61
S86 62
S87 63
S88 64
Device ID number settings (Device ID)..............002+.+...-Default value: 17
The device ID number is an identification number that is used when transmitting and receiving
exclusive messages. The RD-600 is able to receive exclusive data that carries the same device ID
number as its own setting. When using exclusive messages to transfer data, the device ID num-
bers of both devices must be set to match.
thevice
If
Range of values: 17-32
#1 PC 1GHS