14. REMOVAL AND REPLACEMENT OF FLOAT SWITCH

1) Go through the steps 1) through 4) in "13. REMOVAL AND REPLACEMENT OF PUMP
MOTOR."
2) Remove the black rubber Connector from the base of the Float Switch.
3) Remove the screws securing the Float Switch Bracket and the stainless steel adjusting
guide.
4) Take off the Hose sleeving the Float Switch leads.
5) Sleeve the leads of the new Float Switch with the Hose.
6) Install the new Float Switch, and replace the removed parts in the reverse order of
which they were removed.
7) Go through the steps 11) through 13) in "13. REMOVAL AND REPLACEMENT OF
PUMP MOTOR."

15. REMOVAL AND REPLACEMENT OF SPRAY TUBE(S)

1) Turn off the power supply. Unplug the icemaker.
2) Remove the Front Panel and the Insulation Panel.
3) Remove the Rubber Hose from the Spray Tube (Water Supply Pipe).
4) Release the Clamp, and disconnect the Rubber Hose.
5) Remove the Spray Tube by squeezing the side tabs.
6) Install the new Spray Tube, and replace the removed parts in the reverse order of
which they were removed.
7) Refit the panels in their correct positions.
8) Plug in the icemaker. Turn on the power supply.