Removing The Moisture Sensor And Metal Oxide Varistors (Mov) - Maytag MGD6500MBK Technical Manual

Table of Contents

Advertisement

REMOVING THE MOISTURE SENSOR AND
METAL OXIDE VARISTORS (MOV)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Open the dryer door.
4. To remove the Moisture Sensor:
a. Remove the rear panel (see
b. Pull out the lint screen.
FOR SERVICE TECHNICIAN'S USE ONLY
page 39
for the procedure).
c. Remove the two top panel screws from the lint screen air duct.
d. Remove the four 1/4" (6 mm) hex head screws from the air duct and
pull air duct away from dryer.
e. Disconnect the two wires from the terminals of the moisture sensor
strips and remove screw attaching sensors to drum.
A. Screw
B. Moisture Sensor Terminal Strips
5. To remove Metal Oxide Varistors (MOV):
Ƀ Unlock and disconnect the moisture sensor harness connector with
the Metal Oxide Varistors (MOV) from the main harness.
A. Sensor MOV
B. Moisture Sensor Harness Connector
A
B
B
A
43