4. Depress the console clip with the putty knife and lift up on the console to
separate from top panel. Tilt console forward for service.
A. Console Clips
To Remove the Top Panel
1. Unplug dryer or disconnect power.
2. Pull out and remove the lint screen.
3. Remove the two top panel screws.
4. While lifting the front corners of the cabinet top, press a plastic putty
knife against the left and right top clips, and release them from the top.
Rotate the top panel up and rest it against a wall.
FOR SERVICE TECHNICIAN'S USE ONLY
REMOVING THE APPLIANCE CONTROL UNIT
(ACU)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
To Remove the Appliance Control Unit (ACU)
IMPORTANT: Electrostatic Discharge (ESD) Sensitive Device.
Failure to follow the ESD precautions outlined at the beginning of
section 3 "Testing" may destroy, damaged, or weaken the main
control assembly
1. Unplug dryer or disconnect power.
2. Perform the procedures on
page 32
panel" before performing the following steps.
3. Disconnect all connectors from the ACU.
"Removing the Console/HMI and top
33