G3 Kit Accessory - Daikin EKHHEU200CV37 Use, Installation And Maintenance Manual

Domestic hot water heat pump monobloc type
Table of Contents

Advertisement

ATTENTION! Horizontal transport is allowed only
for the last km according to that indicated (see
"Positions not allowed for transport and han-
dling"), making sure supports are positioned in
such a way at the bottom of the boiler so as not
to stress the upper part, as it is not structural.
During horizontal transport the display must
face upwards.
Position allowed only for the last km
Positions not allowed for transport and handling
User, Installations and Maintenance Manual
fig. 2

4. G3 KIT ACCESSORY

It is mandatory that the installation complies with part G3 of the
Building Regulations. For that the unit is factory equipped with
a T/P safety relief valve (set = 90°C/7bar) and is supplied with a
G3 kit composed by:
a) 1x PRSV: Pressure reducing valve/pressure relief valve
combination (check valve, water pressure regulator de-
fault =3,5 bar, water pressure safety valve set=6bar), wa-
ter inlet and water outlet 22 mm connection, discharge pip-
ing connection 15 mm
b) 1x Adaptor (22 mm×3/4" Female BSP)
c) 1x Tee piece (22 mm×22 mm×22 mm)
d) 2x tundishes (15 mm inlet, 22 mm outlet)
e) Wall mounting set for expansion vessel
f) 1x expansion vessel 24 liters preset=3,5bar male connec-
tion 3/4" BSP
NOTE: All piping MUST be installed according to section
G3 of the Building Regulations.
a
b
c
d
e
f
fig. 3
Page 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhheu200pcv37Ekhheu260cv37Ekhheu260pcv37