To Remove The Accessories From The Outdoor Unit; Accessory Pipes: Diameters; To Remove The Transportation Stay - Daikin VRV IV+ RXYTQ8U5YF Installer And User Manual

Heat pump for high ambient temperatures
Table of Contents

Advertisement

14
|
About the box

14.4 To remove the accessories from the outdoor unit

14.5 Accessory pipes: Diameters

14.6 To remove the transportation stay

Installer and user reference guide
50
8 HP
Make sure that all accessories are available in the unit.
a
b
a General safety precautions
b Installation manual and operation manual
c Additional refrigerant charge label
d Installation information sticker
e Piping accessory bag
Accessory pipes (mm)
Gas pipe
Front connection
ID Øa
ID Øb
Bottom connection
ID Øa
OD Øb
Liquid pipe
Front connection
ID Øb
ID Øa
Bottom connection
ID Øa
Only for 14+16 HP
10~16 HP
c
d
REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
No.
1
2
3
4
5
6
7
8
9
10
MODELNAME
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
INSTALLATION
SITE
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
Total indoor unit
No.
11
12
13
14
15
16
17
18
19
20
kg
capacity connection
MODELNAME
Total indoor unit capacity
ratio (CR)
50%< CR < 105%
8HP
0
10-12HP 14-16HP 18-20HP
0
0
0.5
INSTALLATION
OUTDOOR
ADDITIONAL CHARGING
PIPE SIZE O22.2 x 0.37
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
PIPE SIZE O19.1 x 0.26
PIPE SIZE O15.9 x 0.18
TOTAL LENGTH OF LIQUID
when piping length <30m
105%< CR < 130%
0.5
0
0.5
0
0.5
0.5
1.0
No.
SITE
21
22
23
24
25
26
27
28
29
30
UNIT
AMOUNT
Total indoor unit capacity
50%< CR < 70%
70%< CR < 85%
0.3
0
0.5
0.5
1.0
kg
(m) x 0.37
(m) x 0.26
(m) x 0.18
when piping length >30m
105%< CR < 130%
85%< CR < 105%
1.2
0.7
1
1.5
1.5
1
1.5
2.0
INSTALLATION
MODELNAME
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
SITE
PIPE SIZE O12.7 x 0.12
PIPE SIZE O9.5 x 0.059
PIPE SIZE O6.4 x 0.022
ONLY FOR RYYQ8~20 MODELS
No.
31
32
33
34
35
36
37
38
39
40
(m) x 0.12
(m) x 0.059
(m) x 0.022
kg
RYYQ8~12
0.9
RYYQ14-16
1.1
RYYQ18-20
1.3
MODELNAME
INSTALLATION
SITE
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
No.
41
42
43
44
45
46
47
48
49
50
MODELNAME
DATE
INSTALLATION
AMOUNT
SITE
RESULT LEAK CHECK
No.
51
52
53
54
55
56
57
58
59
60
MODELNAME
DATE
INSTALLATION
SITE
AMOUNT
No.
61
62
63
64
MODELNAME
RESULT LEAK CHECK
INSTALLATION
DATE
SITE
AMOUNT
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
SETTING
VALUE
REMARK
DATE
SETTING
VALUE
REMARK
DATE
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
3. RECORD OF INSTALLATION DATE
DAY
MONTH
YEAR
4. MODEL NAME
5. MANUFACTURING NUMBER
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
3P328191-1
3P328192-1
HP
8
10
12
14
16
8
10
12
14
16
ID Øb
e
Øa
25.4
19.1
22.2
28.6
9.5
9.5
12.7
12.7
VRV IV+ heat pump for high ambient temperatures
4P561157-1B – 2021.11
Øb
RXYTQ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents