Instructions For Use; Control Panel Description - Ariston 80 L Manual

Hybrid electric water heater wi-fi
Hide thumbs Also See for 80 L:
Table of Contents

Advertisement

Available languages

Available languages

Hybrid electric water heater (WiFi model) – OPERATING AND MAINTENANCE INSTRUCTIONS FOR THE USER
Hot and cold water separately
No storage
No
circulation of
circulation of
hot water
hot water
C.1
Rif. In Allegato C
Temp.
-
≥ 50°C
≤ 3 l
Ristagno
-
Sedimento
-
Temperature ≥ 55°C the whole day or at least 1h per day ≥60°C.
The volume of water contained in the pipework between the circulation system and the tap which has the greatest distance to the system.
Remove the sediment from the storange water heater in accordance with the local conditions but at least once a year.
Thermal disinfection for 20 min at a temperature of 60°C, for 10 min at 65°C or for 5 min at 70°C at every draw-off point at least once a
week.
The water in the circulation loop shall be not less than 50°C.
No requirement.
If, for some reason, one of the aforementioned "Favourable conditions for the proliferation of Legionella " occurs, it is
strongly recommended that you enable this function by following the instructions listed in this manual [see section 7.11].
In any event, the thermal sanitisation cycle is not capable of completely destroying all Legionella bacteria in the storage
tank. For this reason, if the function is disabled, the Legionella bacteria could return.
Note: when the software performs the thermal sanitisation treatment, it is likely that the storage water heater will
consume more energy.
Warning: when the software has just completed the thermal disinfection treatment, the water temperature could cause
severe burns instantly. Children, the disabled and the elderly are at a higher risk of burns. Check the
temperature of the water before having a bath or a shower.
The default value is 60°C, which can be increased up to 75°C by means of the P23 parameter in the information menu
(see sect. 7.10)
7

INSTRUCTIONS FOR USE

7.1

Control panel description

Refer to Fig. 9.
The six key control panel is simple and logical.
In the upper part of the DISPLAY, the detected temperature is shown. Press the
temperature. The DISPLAY also provides other specific information such as the operation mode notification, the fault
codes, the settings and information about the product status.
Below the display is the
electrical heating element.
Symbol
Description
ON/OFF button turns the product ON and OFF
SET button used to modify the parameters and confirm the changes
Minus button: decreases the temperature, the time and changes the ON/OFF parameter options in
the installer menu
Plus button: increases the temperature, the time and changes the ON/OFF parameter options in the
installer menu
MODE button: changes the operation mode (GREEN, i-MEMORY, PROG 1, PROG 2, PROG 1 +
PROG 2
Button Wi-Fi: switch on/off Wi-Fi mode
Table 2 - Types of hot water installation
Storage
With
No
With
circulation of
circulation of
hot water
hot water
C.2
C.3
C.4
In the
storage
e
e
≥ 50°C
water
heater
a
b
≤ 3 l
b
-
-
Remove
C
Remove
C
LED, which signals the operating status of the water heating in the heat pump or
Mixed hot and cold water
No storage upstream of mixing
Storage upstream of mixing
valves
No circulation
With circulation
of hot water
of hot water
circulation of
mixed water
C.5
C.6
Thermal
Thermal
disinfection
d
disinfection
d
≤ 3 l
b
-
-
-
Remove
118
No storage upstream of
valves
No
With circulation
No circulation
of mixed water
of mixed water
C.7
C.8
C.9
In the
e
≥ 50°C
storage
Thermal
Thermal
water
disinfection
disinfection
d
heater
a
≤ 3 l
b
-
C
Remove
C
button to display the set
mixing valves
With
circulation of
mixed water
C.10
Thermal
d
disinfection
d
≤ 3 l
b
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

100 l

Table of Contents