HP ProDesk 405 G4 Small Form Factor Maintenance And Service Manual page 109

Business pc
Table of Contents

Advertisement

Control panel message
008–Microcode Patch Error
009–PMM Allocation Error during MEBx
Download
00A-Product Information Not Valid
00B-MEBx Module did not checksum correctly
00C-PMM Deallocation Error during MEBx
Cleanup
00D-Setup Error during MEBx Execution
00E-Inventory Error during MEBx Execution
Description
RTC (real-time clock) battery may need to
be replaced.
Processor is not supported by the BIOS.
Memory error during POST execution of
the Management Engine (ME) BIOS Extensions
option ROM.
The product information programmed into
the system board is missing or invalid.
Memory error during POST execution of
the Management Engine (ME) BIOS Extensions
option ROM.
Memory error during POST execution of
the Management Engine (ME) BIOS Extensions
option ROM.
MEBx selection or exit resulted in a setup failure.
BIOS information passed to the MEBx resulted in
a failure.
Recommended action
the problem persists, replace the RTC battery.
See the Removal and Replacement section for
instructions on installing a new battery.
1.
Upgrade BIOS to proper version.
2.
Change the processor.
1.
Reboot the computer.
2.
Unplug the power cord, reseat the memory
modules, and reboot the computer.
3.
If the memory configuration was recently
changed, unplug the computer, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
Use Computer Setup to update this information.
1.
Reboot the computer.
2.
Unplug the power cord, reseat the memory
modules, and reboot the computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
Unplug the power cord, reseat the memory
modules, and reboot the computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
Unplug the power cord, reseat the memory
modules, and reboot the computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
POST numeric codes and text messages
99