4. Collect Service log and contact Lenovo support to schedule PMEM replacement.(Note: Unless
otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or
parts that have reached their maximum usage limitations do not qualify for warranty service.)
• FQXSFMA0033M: Intel Optane PMEM persistent memory interleave set has [arg1] PMEMs(DIMM
[arg2]), [arg3] DIMMs' location is not correct.
Severity: Warning
Parameters:
[arg1]: Number of Dimms In the Interleave [arg2]: Dimm Silk Label list [arg3]: Number of Dimms whose
location is error
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0034M logs will provide the correct location for PMEMs.
4. Move all PMEMs of error message FQXSFMA0034M logs to the correct location.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0034M: DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory interleave set
should be moved to DIMM slot [arg3] in sequence.
Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: Dimm UID [arg3]: Expected Dimm slot number
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. Details included in this error message will provide the correct location for that PMEM.
4. Move the PMEM to the correct location.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0035M: Intel Optane PMEM interleave set should have [arg1] PMEMs, but [arg2] PMEMs
are missing.
Severity: Warning
Parameters:
[arg1]: Number of dimms in the interleave [arg2]: Number of lossed dimms
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0036M logs will provide the details which PMEMs are
missing.
4. Find all missing PMEMs of error message FQXSFMA0036M logs and install them in the correct
location.
.
169