Lenovo ThinkSystem SR950 V3 Manual page 171

Messages and codes reference
Hide thumbs Also See for ThinkSystem SR950 V3:
Table of Contents

Advertisement

• FQXSFMA0028K: Memory Capacity exceeds CPU limit. [arg1]
Severity: Error
Parameters:
[arg1]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Remove AC power from the system.
2. Modify memory configuration to ensure the memory capacity does not exceed the processor part
number limit.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0028M: DIMM [arg1] Self-healing, attempt post package repair (PPR) exceeded DIMM
level threshold [arg2] at Rank [arg3] Sub Rank [arg4] Bank [arg5] Row [arg6] on Device [arg7].
[arg8]
Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: PprAttemptThreshold [arg3]: Rank number [arg4]: Subrank
number [arg5]: Bank number [arg6]: Row number [arg7]: DramDevice [arg8]: DIMM identifier consists of S/
N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and re-enable the DIMM. Reboot the system.
3. Update UEFI firmware to the latest version.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0029I: The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM.
[arg2]
Severity: Info
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU
0123456"
User Action:
Information only; no action is required.
• FQXSFMA0030K: Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]% and still
functioning.
Severity: Warning
Parameters:
.