Lenovo ThinkSystem SR950 V3 Manual page 107

Messages and codes reference
Hide thumbs Also See for ThinkSystem SR950 V3:
Table of Contents

Advertisement

Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0811
User Action:
Information only; no action is required.
• FQXSPPW4001I: PCIe Power Brake for [arg1] has been [arg2].
This message is for the use case where PCIe Power Brake.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0243
User Action:
Check if system have fan fail error, Raidlink CEM fail occurring or Ambient temperature over 35C,
implement the "error" service action to recovery the system and reduce ambient temperature under 35C.
• FQXSPSD0000I: The [StorageVolumeElementName] has been added.
This message is for the use case when an implementation has detected a Drive has been Added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0162
User Action:
Information only; no action is required
• FQXSPSD0001L: The [StorageVolumeElementName] has a fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps:
1. Make sure that the reported device is compatible by checking https://static.lenovo.com/us/en/
serverproven/index.shtml.
2. Collect the service data log from the management controller interface and contact Lenovo Support.
.
Chapter 2
XClarity Controller events
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dc47dc57dc6

Table of Contents