Lenovo ThinkSystem SR950 V3 Manual page 103

Messages and codes reference
Hide thumbs Also See for ThinkSystem SR950 V3:
Table of Contents

Advertisement

Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
• FQXSPPW0110M: Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0810
User Action:
Complete the following steps until the problem is solved:
1. Check if any power adapter is missing, failing or not installed properly. If so, re-install or replace it.
2. Check the power adapter max rate and power capping policy. If the required power resource is not
met, change the power adapter or modify power capping mechanism.
• FQXSPPW2001I: [PowerSupplyElementName] has been removed from container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been
removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0085
User Action:
Information only; no action is required
• FQXSPPW2002I: [PowerSupplyElementName] has returned to OK status.
This message is for the use case when an implementation has detected a Power Supply return to normal
operational status.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0087
.
Chapter 2
XClarity Controller events
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dc47dc57dc6

Table of Contents