Locking The Keyboard; Resetting The Parameters; Reading Data; Counters - Dimplex Edel 200 WATER/3 Installation Manual

Domestic hot water heat pump
Table of Contents

Advertisement

6.9.4 - Locking the keyboard

Automatic and permanent locking
The «locking» menu enables you to create three possible levels of
locking for accessing the menus.
In the «Installer» menu turn the dial to «locking.».
lo ck i ng
NO
= Locking is not activated, but manual
locking is possible by pressing
for 3 seconds.
AUTO
= To lock menu access with temporary unlocking (60
seconds) press
5 0
0
C
p r o
= To lock access to menus with
temporary unlocking (300 seconds)
is possible by pressing
seconds and then
for 3 seconds.
5 0
C
0
• When locking is activated, it is only possible to access unlocking
and to reset the alarm.
Manual locking from the main screen
It is possible to manually lock the keyboard from the main screen
without gaining access through the «Installer menu» provided that
locking settings are not already in place.
Press for 3
seconds
To lock manually, press
-
INSTALLER
l ock ing
Select the level of
locking
Confi rm
for 3 seconds.
unl ock ing
Select ye s
Press for
3 seconds
Confi rm
for 3
and
unl ock ing
Press for
3 seconds
l ock ing
for 3 seconds.
DOMESTIC HOT WATER HEAT PUMP 200L & 270L

6.9.5 - Resetting the parameters

Resetting the parameters allows you to return to the default settings.
Go to the «Installer menu», and turn the dial to «Reset PARa.».
r ese t p a ra .
n o

6.9.6 - Reading data

The «READ DATA» menu shows you, in real time, the information
given by the sensors.
In the «Installer» menu, turn the dial to «display».
Display
n o
wa t er
fl oo r
ev a p
PV mode
If
follows:
s he dd i ng
hygrostat
n o
PV mode
If
p v e co
pv m ax
The temperature which is permanently displayed on the screen is the
set temperature and does not necessarily indicate the temperature
of the water immediately available in the tank.

6.9.7 - Counters

The «Counters» menu shows the number of start-ups from the heat
pump and the electrical back-up.
In the «Installer», menu turn the dial to «counters».
COunt e rs
r ese t p a ra .
Description
Domestic hot water temperature
in lower part of tank
part of tank
Temperature of water
returned from the underfl oor
heating circuit
Temperature of heat pump
evaporator (expansion valve
outlet)
(deactivated) factory settings, read data as
Off -peak hours switch
(0-on; 1- off )
Moisture sensor input
(0-on; 1- off )
(activated) read data as follows:
Contact input 1
(0-open; 1- closed)
Contact input 2
(0-open; 1- closed)
COu nter N° 1
-
Number of start-ups from
the heat pump
COu nter N° 2
-
Number of start ups from
the electrical back-up
COu nter N° 4
-
Accumulated heat pump
running time
-
MANUAL
yes
yes
Select
Confi rm
Reference on
electronics
board
Teau
Tair
Tdegiv
heures creuses
hygrostat
1
heures creuses
2
hygrostat
:
:
:
23