Lennox A98USMV Installation Instructions Manual page 44

Warm air gas furnace upflow/horizontal left/right air discharge direct vent
Table of Contents

Advertisement

Thermostat
DIP Switch 1
Dual Fuel Single-
Stage Heat Pump
Thermostat w/dual
fuel capabilities
Capable of 2-stage
gas heat control
Dual Fuel Two-
Stage Heat Pump
Thermostat w/dual
fuel capabilities
Capable of 2-stage
gas heat control
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the integrated control.
Table 18. Field Wiring for Non-Communicating Thermostat Applications
Page 44 of 74
DIP Switch Settings and On-Board Links
W915
(Y1 to Y2)
Two-Stage
Cooling
OFF
Intact
OFF
Cut
W914
W951
(DS to R)
(Oto R)
Dehumidification
Heat Pumps
Intact
Cut
Intact
Cut
Issue 2346
Wiring Connections
FURNACE
HEAT PUMP
TERM. STRIP
T'STAT
H
H
L
Y2
D
B
Y2
T
outdoor
T
FURNACE
T'STAT
TERM. STRIP
HEAT PUMP
H
H
L
Y2
D
out blue
B
T
outdoor
sensor
T
508364-01
L
Y
sensor
L
Y2
Y2