Lennox A98USMV Installation Instructions Manual page 13

Warm air gas furnace upflow/horizontal left/right air discharge direct vent
Table of Contents

Advertisement

VENT
Capacity
PIPE DIA.
(in.)
1-1/2
1
2
070
2-1/2"
3
2
090
2-1/2"
3
2
110
2-1/2"
3
135
3
2 inch to 1-1/2 inch reducer required, must be field provided.
1
* Requires field provided end installed 1-1/2" exhaust accelerator.
** Kit 51W11 is provided with a 1-1/2" accelerator which must be used for all 45,000 and 70,000 furnace installations. When using
1-1/2 in. piping, the pipe must be transitioned to 2 in. pipe when used with the Flush Mount Kit.
+ Termination kits 44W92, 44W93, 30G28 & 81J20 approved for use in Canadian installations to meet CSAB149.
++ The 44W92 Concentric kit is provided with a 1-1/2" accelerator which must be installed on the exhaust outlet when this kit is used
with the 45,000 and 70,000 furnaces. When using 1-1/2 in. piping, the pipe must be transitioned to 2 in. pipe when used with the
Concentric Kit.
NOTE: The exhaust collar on all models is sized to
accommodate 2" Schedule 40 vent pipe. In horizontal
applications, transition to exhaust pipe larger than 2" must
be made in vertical runs of the pipe. A 2" elbow must be
added before the pipe is transitioned to any size larger
than 2". This elbow must be added to the elbow count used
to determine acceptable vent lengths. Contact Allied Air
Technical Service for more information concerning sizing
of vent systems that include multiple pipe sizes.
IMPORTANT
Do not use screens or perforated metal in exhaust or
intake terminations. Doing so will cause freeze-ups and
may block the terminations.
508364-01
STANDARD
Outdoor
Outdoor
Exhaust
Exhaust
Accelerator
Accelerator
(Dia. X Length)
(Dia. X Length)
1-1/2" x12"
2" x12"
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Flush Mount
1-1/2"
Kit
Concentric Kit
71M80
51W11**
OR
+44W92++
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Table 3.
Min. Vent
Capacity
Length
070
090
15 ft
110
135
Table 4. Minimum Vent Pipe Lengths
Issue 2346
CONCENTRIC
2" Concentric
3" Concentric
Kit
69M29
60L46
OR
+44W92++
44W93+
YES
YES
YES
YES
YES
YES
Example
5 ft. plus 2 elbows of 1-1/2", 2", 2-1/2"
or 3" diameter pipe
5 ft. plus 2 elbows of 2", 2-1/2" or 3"
diameter pipe
5 ft. plus 2 elbows of 2-1/2" or 3"
diameter pipe
5 ft. plus 2 elbows of 3" diameter pipe
Page 13 of 74