Lennox A98USMV Installation Instructions Manual page 41

Warm air gas furnace upflow/horizontal left/right air discharge direct vent
Table of Contents

Advertisement

COMBUSTION
AIR INDUCER
CONNECTOR
DIAGNOSTIC
PUSH BUTTON
DIP SWITCHES
OUTDOOR AIR
TERMINALS
DISCHARGE AIR
TERMINALS
FACTORY TEST
HEADER PINS.
FACTORY USE ONLY.
E43 OUTDOOR
E44 INDOOR
RS-BUS LINK (E3, future use)
I+ = DATA HIGH CONNECTION
I - = DATA LOW CONNECTION
RS-BUS OUTDOOR (E43)
R = 24VAC
I + = DATA HIGH CONNECTION
I - = DATA LOW CONNECTION
C = 24VAXC COMMON
RS-BUS INDOOR (E44)
R = 24VAC
I + = DATA HIGH CONNECTION
I - = DATA LOW CONNECTION
C = 24VAXC COMMON
1/4" QUICK CONNECT TERMINALS
HUM = 120 VAC OUTPUT TO HUMIDIFIER
XMFR = 120 VAC OUTPUT TO TRANSFORMER
LI = 120 VAC INPUT TO CONTROL
CIRC = 120 VAC OUTPUT TO CIRCULATING BLOWER
EAC = 120 VAC OUTPUT TO ELECTRICAL AIR CLEANER
NEUTRALS = 120 VAC NEUTRAL
508364-01
FLAME
SENSE
SENSOR
SENSOR
E3
E43
Figure 56. Integrated Control
7-SEGMENT
DIAGNOSTIC LED
E44
THERMOSTAT CONNECTIONS (E7)
DS = DEHUMIDIFICATION SIGNAL
W2 = HEAT DEMAND FROM 2ND STAGE T/STAT
W1 = HEAT DEMAND FROM 1ST STAGE T/STAT
R = CLASS 2 VOLTAGE TO THERMOSTAT
G = MANUAL FAN FROM THERMOSTAT
C = THERMOSTAT SIGNAL GROUNCONNECTED TO
TRANSFORMER GRD (TR) & CHASIS GROUND (GRD)
Y1 = THERMOSTAT 1ST STAGE COOL SIGNAL
Y2 = THERMOSTAT 2ND STAGE COOL SIGNAL
O = THERMOSTAT SIGNAL TO HEAT PUMP REVERSING
VALVE
H = 24V HUMIDIFIER OUTPUT. DO NOT CONNECT TO
COMFORT SYNC® THERMOSTAT
L
= USE ONLY WITH A COMMUNICATING THERMOSTAT
AND A NON-COMMUNICATING OUTDOOR UNIT
DH = DEHUMIDIFICATION OUTPUT COMMUNICATING
THERMOSTAT ONLY
Issue 2346
NEUTRAL
TERMINALS
IGNITOR
CONNECTOR
LINE VOLTAGE
TERMINALS
HUM
EAC
INDOOR
BLOWER
CONNECTOR
W915 Y1 TO Y2
W951 R TO O
W914 R TO DS
W915
W951
L - use only with
W914
communicating T'stat and
non-communicating outdoor
unit.
Page 41 of 74