12: "ERROR MESSAGE" ADDENDUM

PDM DISPENSER
Error Message
Tie in Tool
Out of ties, or Tie in Dispenser
Tie in Hose - Press "Air Burst"
Blocked or Dirty Tool Sensor, or
Tie Stuck in Tool Sensor
Blocked or Dirty Exit Sensor, or
Tie Stuck in Exit Sensor
OPERATION MANUAL
PHM HOSE
a.
Remove cable tie and continue
b.
If this happens often, change hose ends
c.
If problem persists after changing hose end, contact
Maintenance Department
a.
Press "Buzzer" button, then "Continue" button
b.
If Out of Ties, get a new reel and load
c.
If not out of ties, press "Load" button once and continue
d.
If problem persists, contact Maintenance
a.
Press "Buzzer" button, then "Air Burst" button, remove
cable tie from jaws of tool. Press "Menu" button, Press
"Reset Load" button, Press "Load" button once, and
continue.
b.
If problem persists, contact Maintenance Department
a.
Press "Buzzer" button, then "Air Burst" button, remove
cable tie from jaws of tool. Press "Menu" button, Press
"Reset Load" button, Press "Load" button once, and
continue.
b.
If cable tie is difficult to remove, contact Maintenance
Department. (Note: Tool damage may occur by trying to
pry out cable tie to remove.)
a.
Press "Buzzer" button, then "Air Burst" button, remove
cable tie from jaws of tool. Press "Menu" button, Press
"Reset Load" button, Press "Load" button once, and
continue.
b.
If cable tie doesn't come out, remove Hose from
Dispenser. Remove cable tie sticking out of Dispenser by
pulling lightly on it. Press "Menu" button, Press "Reset
Load" button, Press "Load" button once, and continue.
c.
If cable tie is stuck (don't pull on it with pliers); or if no
cable tie is present, contact Maintenance Department.