Daikin FCA71AV16 Installation Manual page 7

Table of Contents

Advertisement

*At least
1500mm
from a wall
- :D
NOTE
• The"*" marked space is at least 500 mm wide if the air outlet is closed.
In case of also closed corner area (corner area of both left right direction for closing air outlet),
it is 200 mm or more.
- � CAUTION------------------------
• Any vents, light fixtures, or other appliances which may disturb the airflow might cause the top side to
become dirty if located too nearby, so follow Fi g . 2 when installing.
Note)
1. This restriction applies to the exposed type lighting, but does not apply to the recessed type (which
does not protrude below the ceiling line).
2. For how to set the airflow direction (including airflow block) with the horizontal blade, refer to
"Individual Airflow Direction" in the operation manual attached to the remote controller.
• Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away from
televisions and radios. This is to prevent image interference and noise in those electrical appliances.
(Noise may be generated depending on the conditions under which the electric wave is generated, even
if 1 meter is kept.)
• If installing the wireless kit, the distance of the signal sent from the remote controller might be shorter if
there are fluorescent lights which are electrically started (such as with inverters, rapid starters, etc.) in
the room. The indoor unit should be installed as far away from fluorescent lights as possible.
(2) Ceiling height
This product can be installed in ceilings up to 3.5 m high (4.2 m high for the 24, 30, and 36).
If the ceiling height is 2.7 m (3.2 m for the 24, 30, and 36) or more, field settings will have to be made
with the remote controller. See "11. FIELD SETTING" for details.
( 3) Air direction
The air direction shown in Fi g . 3 is an example.
Select the appropriate number of directions according to the shape of the room and the location of the unit.
(Field settings have to be made using the remote controller and the outlet vents have to be shut off if two,
three, or four (corner shut-off) directions are selected. See the shut-off materials (sold separately)
installation manual for details.)
(4) Use suspension bolts for installation. Check if the location for the installation is strong enough to support
the weight of the unit, reinforce it if necessary, and install using suspension bolts. (The spacing of the
installation is shown on the "paper pattern for installation (5)".)
,--------, ,-----� ,-----� ,-----�
◊oi ◊oi ◊o
Model
FCA71AV16
Indoor unit
I
I At least
1500mm
At least 2000mm
(NOTE)
/
� o om
O m � o m
o ◊ �
All-round air
Four air direction Three air direction Two air direction
H(mm)
BYCQ125EAF6
BYCQ125EAK
261
I
I
At least 4000mm
Fi g . 2
[Air direction]
f
o ◊
Fi g . 3
6
Indoor unit
I
I

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rzca71av16

Table of Contents