Advertisement
Please read this Instruction Manual thoroughly before using the unit.
Please keep this Instruction Manual for future reference.
The Body Composition Monitor is equipped with an automatic recognition function to recognize who is using the monitor in accordance with the registered personal data.
How does automatic recognition works?
Be sure to register your personal data before using the automatic recognition function.
Refer to REGISTERING PERSONAL DATA
Your Personal Profile Number will be displayed after the measurement.
Check your Personal Profile Number.
If inaccurate recognition continues, select your Personal Profile Number before taking a measurement.
Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A MEASUREMENT.
Display and Buttons
Display
The illustration shows all display items.
Operation Buttons
Touch the buttons with your fingers.
Button
Touch the button to return. Touch continuously to recede rapidly.
Button
Displays the result of the last measurement.
Symbol
Lights when the operation buttons are touched.
Button
Touch the button to advance. Touch continuously to advance rapidly.
Button
Power ON... Touch
Power OFF... Touch and hold
Confirm Value and Set... Touch
Main Unit
Battery Life and Replacement
About the Power Off Function
In order to measure your weight accurately, the product will correct the deviation caused by gravitational acceleration. Accurate measurement cannot be conducted if the area of the usage place, date and time are not correctly set.
To use the automatic recognition function, you must register your personal data in advance.
You can register personal data of up to 4 persons.
Those whose personal data have not been registered can use a Guest mode to measure his/her body composition.
What is a Guest mode? Refer to For Those Who Use the Guest Mode to Take a Measurement.
CORRECT MEASUREMENT METHOD
When the automatic recognition function is used to take a measurement, register your personal data in advance.
Refer to REGISTERING PERSONAL DATA.
Even if you do not have personal data information stored on the unit, you can use Guest mode to measure body composition.
When "No.1" to "No.4" blink or when "GUEST" is displayed, your Personal Profile Number cannot be registered.
Select the Personal Profile Number you want to register with the or button and touch the (SET) button to make a confirmation to register the personal data.
Refer to REGISTERING PERSONAL DATA.
Wrong Personal Profile Number may be displayed in the following cases.
VIEWING THE LAST MEASUREMENT RESULTS
For Those Who Use the Guest Mode to Take a Measurement
What is a Guest mode?
With this mode, you can measure your body composition without registering your personal data in advance by entering your date of birth, gender and height each time. When the Guest mode is used to take a measurement, the last measurement result cannot be checked.
Even if you measure your weight only, it is necessary for you to register your personal data.
If your Personal Profile Number is used by someone else, delete it and make a registration again instead of changing it.
To Change Personal Data
Now, you have successfully changed your personal data.
You can continue to measure your body composition. If you do not take a measurement, touch the button for 3 seconds or longer to turn off the power.
To Delete Personal Data
Now, you have successfully deleted your personal data.
Touch the button for 3 seconds or longer to turn off the power.
<BMI>
In accordance with the international index to judge obesity, an ideal body weight is at BMI "22". *The obesity classification standard advocated by Japan Society for the Study of Obesity (Year 2000).
BMI = weight (kg)÷height (m)÷height (m)
<Resting metabolism>
Energy necessary for life sustaining. Ministry of Health, Labor and Welfare: Dietary Reference Intakes of Japanese people (2010 version)
Age (Years old) | Male | Female | ||
Standard Body Weight (kg) | Resting Metabolism (kcal/day) | Standard Body Weight (kg) | Resting Metabolism (kcal/day) | |
6 to 7 | 22.0 | 980 | 22.0 | 920 |
8 to 9 | 27.5 | 1,120 | 27.2 | 1,040 |
10 to 11 | 35.5 | 1,330 | 34.5 | 1,200 |
12 to 14 | 48.0 | 1,490 | 46.0 | 1,360 |
15 to 17 | 58.4 | 1,580 | 50.6 | 1,280 |
18 to 29 | 63.0 | 1,510 | 50.6 | 1,120 |
30 to 49 | 68.5 | 1,530 | 53.0 | 1,150 |
50 to 69 | 65.0 | 1,400 | 53.6 | 1,110 |
70 and above | 59.7 | 1,280 | 49.0 | 1,010 |
*The basic value is a standard. The product calculates the resting metabolism in accordance with the body composition result.
<Body Fat Percentage>
It is the proportion of the weight of body fat to the body weight.
<The obesity classification value advocated by Lohman (in 1986) and Nagamine (in 1972) is used as a reference>
<Visceral Fat Level>
A level to reflect the size of fat area adhered around viscera based on the data of our company.
Visceral fat level | Level Classification |
1 to 9 | 0 (Normal) |
10 to 14 | + (High) |
15 to 30 | ++ (Very High) |
*The body fat percentage is low while the visceral fat level is high sometimes. On the contrary, the body fat percentage is high while the visceral fat level is low.
*The visceral fat level is the standard to the last. Consult a doctor for medical diagnosis.
<Skeletal Muscle Percentage>
It is the proportion of the weight of skeletal muscle to the body weight. Skeletal muscle is the muscle that can be trained (increased) through sports.
Skeletal Muscle Percentage | Classification | |
Male | Female | |
5.0 to 32.8% | 5.0 to 25.8% | - (Low) |
32.9 to 35.7% | 25.9 to 27.9% | 0 (Normal) |
35.8 to 37.3% | 28.0 to 29.0% | + (High) |
37.4 to 60.0% | 29.1 to 60.0% | ++ (Very High) |
* Based on our data
<Body Age>
It is the age of the body calculated in accordance with resting metabolism. A comprehensive classification is made in accordance with the comparison between body age and actual age.
Error Display | Cause | Correction |
| You step off the unit during the measurement. | Do not step off the unit till the measurement is completed. (Refer to CORRECT MEASUREMENT METHOD.) |
Your feet are not correctly positioned on the electrodes. | Make sure that you are standing on the unit correctly and try again. (Refer to CORRECT MEASUREMENT METHOD. ) | |
The measurement position is not stable or your feet are not placed correctly. Feet are too dry. | Remain still and do not move during measurement. Slightly moisten the soles of your feet with a damp towel and try again. (Refer to CORRECT MEASUREMENT METHOD. ) | |
The unit is not set up correctly. | Remove the batteries. Wait 1 minute. Reinstall the batteries. Touch the button and turn on the power. Retake the measurement. | |
You step onto the unit before 0.0 kg is displayed. | Wait until 0.0 kg is displayed before stepping onto the unit. | |
The unit moved before 0.0 kg is displayed. | Do not move the unit until 0.0 kg is displayed. | |
Movement during measurement. | Do not move till measurement is completed. | |
When measuring, body weight range is exceeded. |
TROUBLESHOOTING TIPS
Problem | Cause | Correction |
Nothing is displayed when the power is turned on | Batteries are not inserted. | Insert the batteries. Refer to BATTERY INSTALLATION. |
The polarities of batteries are not aligned correctly. | Insert the batteries in correct alignment. Refer to BATTERY INSTALLATION. | |
The batteries are worn out. | Replace the batteries with new ones. Refer to BATTERY INSTALLATION. | |
"0.0 kg" is displayed or the weight value barely increases even when you step onto the unit. | You stepped onto the unit before "0.0 kg" was displayed. | Wait until "0.0 kg" is displayed before stepping onto the unit. |
The value of body weight is displayed abnormally high or low. | ||
The measured value is displayed abnormally high or low. The measured values vary widely for each measurement. | Your posture is not correct and measurement cannot be taken. | Stand still in the correct posture to take a measurement. Refer to CORRECT MEASUREMENT METHOD. |
The measurement is taken on soft floor surface such as carpet or uneven floor surface. | Place the unit on a hard and level floor. | |
The soles of your feet, or whole body are cold, causing poor blood circulation | Warm yourself up, and then take a measurement once you feel your circulation is back to normal. | |
The electrodes are extremely cold. | Place the unit in a warm room for a few minutes, and then take a measurement when you feel cold no longer by touching the electrodes. | |
Feet are too dry. | Slightly moisten the soles of your feet with a damp towel and try again. | |
You are not correctly recognized by the automatic recognition function. | Your body weight has changed a lot since last measurement. | Select your personal profile number before measurement. |
Your body type and weight are similar to another user who has been registered. | Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A MEASUREMENT. | |
You want to measure your body composition, but body composition measurement does not start after the weight measurement has been displayed. | You select "No.0" for your body weight only. (A Personal Profile Number or GUEST is not displayed) | Select your Personal Profile Number or GUEST correctly before making a measurement. Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A MEASUREMENT. |
Nothing happened when you touch the buttons | The buttons are wet or dirty. | Wipe the water or dirt off the buttons and try again. |
You touch the buttons while standing on the main unit. | Step off the main unit before touching them. | |
You touch two or more buttons at the same time. | Touch the buttons one by one. | |
Some result is displayed as "" | The registered value or the body composition value exceeds the measurement range available. | Please check whether the date, date of birth, gender and height settings are wrong. Refer to CHANGE/DELETE PERSONAL DATA. Even if the date, date of birth, gender and height are correctly set, you may not take a measurement in case that they exceed the measurement range available or the user is under a suitable age. Refer to SPECIFICATIONS display. |
The power is automatically turned off | Refer to About the Power Off Function on BATTERY INSTALLATION. |
Product Name | Body Composition Monitor | ||
Model | HBF-224 (HBF-224-APDB) | ||
Display* | Body Weight: | 2 to 100 kg with an increment of 0.1 kg 100 to 135 kg with an increment of 0.2 kg | |
Weight Gap: | -99.9 to 99.9kg | ||
BMI: | 2.5 to 90.0 with an increment of 0.1 | ||
Body Fat percentage: | 5.0 to 50.0% with an increment of 0.1% | ||
Body fat percentage classification: | - (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels | ||
Resting Metabolism: | 385 to 3999 kcal with an increment of 1 kcal | Above 6 years old | |
Skeletal Muscle percentage: | 5.0 to 60.0% with an increment of 0.1% | ||
Skeletal muscle percentage classification: | - (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels | ||
Visceral Fat Level: | 1 to 30 level with an increment of 1 level | Above 18 years old | |
Visceral fat level classification: | 0 (Normal) / + (High) / ++ (Very High) 3 levels | ||
Body Age: | 18 to 80 years old with an increment of 1 year | ||
Memory: | Last measurement results | ||
Set Items | Gravity correction: | Select "2" as the area code | |
Date: | January 1, 2016 to December 31, 2040 | ||
Time: | 0.00 to 23:59 24-hour notation | ||
Personal data information: | The following information can be stored for up to 4 people. | ||
Date of birth: | January 1, 1900 to December 31, 2040 | ||
Gender: | Male/female | ||
Height: | 100.0 to 199.5 cm with an increment of 0.5 cm | ||
Remark: | You will need to set up these information each time you take a measurement as "GUEST". | ||
Weight Accuracy | Above 2.0 kg to 40.0 kg: ±400 g Above 40.1 kg to 135.0 kg: ±1% | ||
Power Supply | 4 AAA manganese batteries (R03) [You may also use 4 AAA alkaline batteries (LR03).] | ||
Battery Life | Approximately 1 year (When AAA manganese batteries are used in accordance with the test condition) | ||
Operating Temperature/Humidity | +5°C to +35°C, 30% to 85% RH | ||
Storage Temperature/ Humidity/Air Pressure | -20°C to +60°C, 10% to 95% RH, 700 hPa - 1060 hPa | ||
Weight | Approximately 1.6 kg (including batteries) | ||
External Dimensions | Approximately 285 (W) × 28 (H) × 280 (D) mm | ||
Package Contents | Body Composition Monitor, trial battery (4 AAA manganese batteries) and instruction manual |
NOTE: Subject to technical modification without prior notice.
*Below 5 years old: Body weight, Weight Gap and BMI can be measured.
Below 17 years old: Visceral fat level and body age cannot be measured.
Above 81 years old: Body composition is for reference.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC's and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2:2007 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electro magnetic emissions for medical devices. This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed:
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN
Asia Pacific HQ
OMRON HEALTHCARE SINGAPORE PTE LTD.
438A Alexandra Road, #05-05/08, Alexandra Technopark, Singapore 119967
www.omronhealthcare-ap.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Omron BodySCAN HBF-224 - Body Composition Monitor Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the BodySCAN that isn't answered in the manual? Leave your question here.