only by licensed authorized technician.
Ensure no following objects are under the indoor unit:
§ Microwaves, ovens and other hot objects.
§ Computers and other high electrostatic appliances.
§ Sockets that plug frequently.
The joints between indoor and outdoor unit shall not be reused,
unless after re-fl aring the pipe.
The specifi cations of the fuse are printed on the circuit board, such
as: 3.15A/250V AC, etc.
If your air conditioner is not fi tted with a supply cord and a plug, an
anti-explosion all-pole switch must be installed in the fi xed wiring
and the distance between contacts should be no less than 2.5 mm.
If your air conditioner is permanently connected to the fi xed wiring,
an anti-explosion residual current device (RCD) having rated
residual operating current not exceeding 30 mA should be installed
in the fi xed wiring.
Power supply circuit should have leakage protector and air
switch of which the capacity should be more than 1.5 times of the
maximum current.
GB
57