4. The recovered refrigerant shall be loaded in the appropriate storage tanks,
attached with a transporting instruction, and returned to the refrigerant
manufacturer. Don't mix refrigerant in recovery equipment, especially a
storage tank.
5. The space loading R32 refrigeration can't be enclosed in the process
of transportation. Take anti electrostatic measures if necessary in
transportation. In the process of transport, loading and unloading,
necessary protective measures must be taken to protect the air conditioner
to ensure that the air conditioner is not damaged.
6. When removing the compressor or clearing the compressor oil, make sure
the compressor is pumped to an appropriate level to ensure that there is no
residual R32 refrigerants in the lubricating oil. The vacuum pumping should
be carried out before the compressor is returned to the supplier. Ensure
the safety when discharging oil from the system.