Contact Heart Rate Grips Replacement - Total Body
Tools Required:
• Phillips screwdriver
• Flat head screwdriver
• Side cutter
• Tape
Time:
30 minutes
Disconnect Power Source
Unplug power cord from power outlet.
WARNING: Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Remove Heart Rate Grips
1. Remove screws securing front and back grip to handle using a Phillips screwdriver.
2. Disconnect the heart rate wires from each grip.
Install Heart Rate Cable
1. Unplug handle heart rate cable from frame heart rate cable.
2. Remove strain relief from arm using a flat head screwdriver.
3. Cut the strain relief off of the heart rate cable using a side cutter.
Item
1
2
3
Screw, Pan Head Phillips, 6-19 x 16
4
5
Item
1
2
3
Page 25 of 79
Description
Grip, Heart Rate, Back
Grip, Heart Rate, Front
Black Heart Rate Wire
Red Heart Rate Wire
Description
Heart Rate Cable, Handle
Heart Rate Cable, Frame
Strain Relief
Qty
1
1
3
1
1
Qty
1
1
1