this depth until air supply limitations require you to surface. When the surface has been
reached, no further diving or flying should take place for a minimum of two days.
Omitted Decompression
The ERROR MODE results from omitted decompression, when the diver stays above
the ceiling for more than three minutes. During this three-minute period the Er warning
will blink alternating with the CEILING/ASC TIME display. The FAVOR AIR will continue
to function normally, if the diver descends below the ceiling within three minutes.
After this the FAVOR AIR will enter a permanent ERROR MODE. In the permanent
ERROR MODE the FAVOR AIR will not show no-decompression or ascent times. Only
a permanent Er warning is shown in the center window. However, all the other displays
will function as before, to provide information for ascent.
In the surface mode, the CEILING/ASC TIME symbol will blink in the center window and
at the dive planning mode a permanent Er is shown instead of no-decompression times
.
Extreme Ceiling Depth Or Decompression Range
When the ceiling descends to a depth deeper than 9 m [30 ft] or when the ASCent TIME
is longer than 63 minutes, the Er warning will start to blink in the center window. If the
diver immediately ascends, the FAVOR AIR will continue to function normally after the
ceiling is back to 9 m [30 ft] or the ASCent TIME is shorter than 63 minutes.
If the ceiling descends to the depth of 12 m [39 ft] even momentarily the FAVOR AIR will
enter the permanent ERROR MODE.