Protected Menus - Toro Groundsmaster 4500-D Operator's Manual

Traction unit
Hide thumbs Also See for Groundsmaster 4500-D:
Table of Contents

Advertisement

About
Menu Item
Model
SN
S/W Rev

Protected Menus

There are 5 operating configuration settings that are
adjustable within the Settings Menu of the InfoCenter: auto
idle, maximum mowing ground speed, maximum transport
ground speed, Smart Power, and deck counter balance. These
settings are in the Protected Menu.
Accessing the Protected Menu Settings
1. From the Main Menu, scroll down to the Settings
Menu and press the right button.
2. In the Settings Menu, scroll down to the Protected
Menu and press the right button.
3. To enter the passcode, use the center button to set
the first digit then press the right button to move on
to the next digit.
4. Use the center button to set the second digit then press
the right button to move on to the next digit.
5. Use the center button to set the third digit then press
the right button to move on to the next digit.
6. Use the center button to set the fourth digit then press
the right button.
7. Press the middle button to enter the code.
Viewing and Changing the Protected
Menu Settings
1. In the Protected Menu, scroll down to Protect Settings.
2. To view and change the settings without entering a
passcode, use the right button to change the Protect
Settings to O
.
FF
3. To view and change the settings with a passcode, use
the left button to change the Protect Settings to O
set the passcode, and turn the key in the ignition switch
to the O
position and then to the O
FF
Setting the Auto Idle
1. In the Settings Menu, scroll down to Auto Idle.
2. Press the right button to change the auto idle time
between O
, 8S, 10S, 15S, 20S, and 30S.
FF
Description
Lists the model number of the
machine.
Lists the serial number of the
machine.
Lists the software revision of
the master controller.
N
position.
N
Setting the Maximum Allowed Mow
Speed
1. In the Settings Menu, scroll down to Mow Speed and
press the right button.
2. Set the maximum allowed mow speed.
Note: Press the right button to increase the max full
mow speed (50%, 75%, or 100%). Press the center
button to decrease the max full mow speed (50%, 75%,
or 100%).
3. Press the left button to exit.
Setting the Maximum Allowed Transport
Speed
1. In the Settings Menu, scroll down to Transport Speed
and press the right button.
2. Set the maximum allowed transport speed.
Note: Press the right button to increase the max
transport speed (50%, 75%, or 100%). Press the center
button to decrease the max transport speed (50%,
75%, or 100%).
3. Press the left button to exit.
Turning the Smart Power ON/OFF
1. In the settings menu, scroll down to Smart Power.
2. Press the right button to switch between O
3. Press the left button to exit.
Setting the Counterbalance
1. In the Settings Menu, scroll down to Counterbalance.
2. Press the right button to select counterbalance and
change between the low, medium, and high settings.
3. When finished with the Protected Menu, press the left
button to exit to the Main Menu, then press the left
button to exit to the Run Menu.
Stationary Regeneration
If the Stationary Regeneration icon appears on the InfoCenter,
refer to the Service Manual or contact your Toro Distributor
,
for the maintenance procedure.
DPF Ash Level
The DPF ash level may be checked by entering the PIN as
described in
Accessing the Protected Menu Settings (page 28)
and navigating to the service section.
28
and O
.
N
FF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4700-d3087330874