Configuring Online Diagnostics
Attribute
Intitial release
Corrective action
Hardware support
TestFantray
This test verifies if the fan tray has been inserted, and is working properly on the board. This test runs every
100 seconds.
Attribute
Disruptive or Nondisruptive
Recommendation
Default
Intitial release
Corrective action
Hardware support
TestPhyLoopback
This PHY loopback test verifies the PHY-level loopback functionality. In this test, a packet, which loops back
at the PHY level and is matched against the stored packet, is sent. It cannot be run as a health-monitoring test.
Attribute
Disruptive or Nondisruptive
Recommendation
Default
Intitial release
Corrective action
Hardware support
TestThermal
This test verifies the temperature reading from a device sensor if it is below the yellow temperature threshold.
This test runs every 90 seconds.
System Management Configuration Guide, Cisco IOS XE Amsterdam 17.2.x (Catalyst 9500 Switches)
Generic Online Diagnostics (GOLD) Tests
Description
Cisco IOS XE Gibraltar 16.10.1.
Displays a syslog message if the test fails for a port.
All modules.
Description
Nondisruptive
Do not disable. This can be run as a health-monitoring
test and also as an on-demand test.
On.
Cisco IOS XE Fuji 16.8.1.
Displays a syslog message if the fan tray is not present
or any of the fans fail.
All modules.
Description
Disruptive.
Run this as an on-demand test as per requirement.
Off.
Cisco IOS XE Fuji 16.8.1.
Displays a syslog message if the test fails for a port.
All modules.
197