POWER MIG 215 MP
®
INSTALLATION
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
Insulate yourself from work and ground.
• Always wear dry insulating gloves.
FUMES AND GASES can be danger-
ous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove
fumes from breathing zone.
WELDING SPARKS can cause fire or
explosion.
• Keep flammable material away.
• Do not weld on closed containers.
ARC RAYS can burn eyes and skin.
• Wear eye, ear and body protection.
Observe all safety information throughout this
manual.
--------------------------------------------------------

INPUT AND GROUND CONNECTIONS

Before starting the installation, check with the local power company
if there are any questions about whether your power supply is
adequate for the voltage, amperes, phase, and frequency specified
on the welder rating plate. Also be sure the planned installation will
meet the U.S. National Electrical Code and local code requirements.
This welder may be operated from a single phase line or from one
phase of a two or three phase line.
The following warning decal is adhered to the input panel located
on the back of the machine. The power cords supplied with the unit
shall only be used with the Power MIG® 215 MP
FIGURE B.1
WARNING
unit.
The Power MIG® 215 MP
Using the instructions in Figure B.2, have a qualified electrician
connect a receptacle (Customer Supplied) or cable to the input
power lines and the system ground per the U.S. National Electrical
Code and any applicable local codes. For cords over 100 foot,
larger copper wires should be used. Fuse the two hot lines with
super lag type fuses as shown in the following diagram. The center
contact in the receptacle is for the grounding connection. A green
wire in the input cable connects this contact to the frame of the
welder. This ensures proper grounding of the welder frame when
the welder plug is inserted into a grounded receptacle.
FIGURE B.2
CONNECT TO A SYSTEM GROUNDING WIRE. SEE THE UNITED STATES
NATIONAL ELECTRICAL CODE AND/OR LOCAL CODES FOR OTHER
DETAILS AND MEANS FOR PROPER GROUNDING. CONNECT TO HOT
WIRES OF A THREE-WIRE, SINGLE PHASE SYSTEM.

LOCATION AND MOUNTING

The Power MIG® 215 MP
will operate in harsh environments. Even
so, it is important that preventative measures are followed in order to
assure long life, reliability, and safe operation.
• The Power MIG® 215 MP
circulation of clean air such that air movement in the back and out the
front louvers.
• Dirt and dust that can be drawn into the Power MIG® 215 MP
should be kept to a minimum. Failure to observe these precautions can
result in excessive operating temperatures and nuisance thermal trips.

HIGH FREQUENCY PROTECTION

During operation, distance the Power MIG® 215 MP
controlled machinery. The normal operation of the Power MIG® 215
MP
may adversely affect the operation of RF controlled equipment,
which may result in bodily injury or damage to the equipment.